Diagnostic
Error
Code
FRU/Action
020-199-XXX
PCI
test
failed,
cause
unknown
1.
Go
to
the
Undetermined
problems
section
2.
Flash
the
system
and
re-test
3.
Replace
component
under
function
test
020-262-XXX
PCI
system
error
1.
PCI
card
2.
Riser
card,
if
installed
3.
System
board
025-000-XXX
IDE
interface
Test
Passed
1.
No
action
025-00X-XXX
025-01X-XXX
IDE
interface
failure
1.
IDE
signal
cable
2.
Check
power
supply
3.
IDE
device
4.
System
board
025-027-XXX
IDE
interface
Configuration/Setup
error
1.
IDE
signal
cable
2.
Flash
the
system
3.
IDE
device
4.
System
board
025-02X-XXX
025-03X-XXX
025-04X-XXX
IDE
Interface
failure
1.
IDE
signal
cable
2.
Check
power
supply
3.
IDE
device
4.
System
board
025-195-XXX
IDE
interface
Test
aborted
by
user
1.
Information
2.
Re-start
the
test,
if
necessary
025-196-XXX
IDE
interface
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
025-197-XXX
IDE
interface
test
warning
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled
2.
Re-run
test
3.
Component
that
is
called
out
in
warning
statement
4.
Component
under
test
025-198-XXX
IDE
interface
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled
2.
Flash
the
system
and
re-test
3.
Go
to
the
Undetermined
problems
section
025-199-XXX
IDE
interface
test
failed,
cause
unknown
1.
Go
to
the
Undetermined
problems
section
2.
Flash
the
system
and
re-test
3.
Replace
component
under
function
test
030-000-XXX
SCSI
interface
Test
Passed
1.
No
action
Chapter
7.
Symptom-to-FRU
Index
99