Diagnostic
Error
Code
FRU/Action
001-038-XXX
System
Extension
failure
1.
Adapter
card
2.
System
board
001-039-XXX
System
DMI
data
structure
error
1.
Flash
the
system
2.
System
board
001-040-XXX
System
IRQ
failure
1.
Power-off/on
system
and
re-test
2.
System
board
001-041-XXX
System
DMA
failure
1.
Power-off/on
system
and
re-test
2.
System
board
001-195-XXX
System
Test
aborted
by
user
1.
Information
2.
Re-start
the
test,
if
necessary
001-196-XXX
System
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
001-197-XXX
System
test
warning
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled
2.
Re-run
test
3.
Component
that
is
called
out
in
warning
statement
4.
Component
under
test
001-198-XXX
System
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled
2.
Flash
the
system
and
re-test
3.
Go
to
the
Undetermined
problems
section
001-199-XXX
System
test
failed,
cause
unknown
1.
Go
to
the
Undetermined
problems
section
2.
Flash
the
system
and
re-test
3.
Replace
component
under
function
test
001-250-XXX
System
ECC
error
1.
System
board
001-254-XXX
001-255-XXX
001-256-XXX
001-257-XXX
System
DMA
error
1.
System
board
001-260-XXX
001-264-XXX
System
IRQ
error
1.
System
board
001-268-XXX
System
IRQ1
failure
1.
Device
on
IRQ1
2.
System
board
001-269-XXX
System
IRQ2
failure
1.
Device
on
IRQ2
2.
System
board
001-270-XXX
System
IRQ3
failure
1.
Device
on
IRQ3
2.
System
board
Chapter
7.
Symptom-to-FRU
Index
91

Table of Contents

Related product manuals