Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
071B Timeout, no action detected. Reinitialize the operation.
Disk unit 12 was powered off but not removed.
Concurrent maintenance informational reference code.
071C Timeout, no action detected. Reinitialize the operation
Device 3 was powered off but not removed.
Concurrent maintenance informational reference code.
071D Timeout, no action detected. Reinitialize the operation
Disk unit K15 was powered off but not removed.
Concurrent maintenance informational reference code.
071E Timeout, no action detected. Reinitialize the operation
Disk unit K16 was powered off but not removed.
Concurrent maintenance informational reference code.
071F Timeout, no action detected. Reinitialize the operation
Device 4 was powered off but not removed.
Concurrent maintenance informational reference code.
0800 Blower B01 powered off for concurrent maintenance
0801 Blower B02 powered off for concurrent maintenance
0802 Blower B03 powered off for concurrent maintenance
0803 Blower B04 powered off for concurrent maintenance
0900 Power Supply P01 powered off for concurrent maintenance
0901 Power Supply P02 powered off for concurrent maintenance
0902 Power Supply P03 powered off for concurrent maintenance
0903 Power Supply P04 powered off for concurrent maintenance
0904 Power Supply P05 powered off for concurrent maintenance
0905 Power Supply P06 powered off for concurrent maintenance
0F0F AC Module Failure
The SPCN node cannot determine the machine type of the box in which it
is installed.
TWRCARD
BACKPLN
21F9429
0F12 Undefined box ID, EEPROM test failed
The SPCN node cannot determine the machine type of the box in which it
is installed.
TWRCARD
BACKPLN
21F9429
0F13 Undefined box ID, Code type mismatch
The SPCN node cannot determine the machine type of the box in which it
is installed.
TWRCARD
BACKPLN
21F9429
0F1F Undefined box ID, LCD test failed
The SPCN node cannot determine the machine type of the box in which it
is installed.
TWRCARD
BACKPLN
21F9429
1xxx
System Reference Codes 85

Table of Contents

Other manuals for IBM iSeries 270

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 270 and is the answer not in the manual?

IBM iSeries 270 Specifications

General IconGeneral
BrandIBM
ModeliSeries 270
CategoryServer
LanguageEnglish

Related product manuals