Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
6C1A Disk Unit 11 regulator fault
A fault detection failure occurred for the regulator that powers disk unit 11.
The regulator or the ac module can cause this fault.
DISKTRY
BKSPCN
6C1B Disk Unit 12 regulator fault
A fault detection failure occurred for the regulator that powers disk unit 12.
The regulator or the ac module can cause this fault.
DISKTRY
BKSPCN
6C1C Device 3 regulator fault
A fault detection failure occurred for the regulator that powers device 3.
The regulator or the ac module can cause this fault.
RMDEV
BKSPCN
6C1D Disk Unit K15 regulator fault
A fault detection failure occurred for the regulator that powers disk unit
K15, located in slot 15 of the disk expansion unit. The regulator or the ac
module can cause this fault.
DISKTRY
BKSPCN
6C1E Disk Unit K16 regulator fault
A fault detection failure occurred for the regulator that powers disk unit
K16, located in slot 16 of the disk expansion unit. The regulator or the ac
module can cause this fault.
DISKTRY
BKSPCN
6C1F Device 4 regulator fault
A fault detection failure occurred for the regulator that powers device 4.
The regulator or the ac module can cause this fault.
RMDEV
BKSPCN
6C20 Disk Unit K17 regulator fault
A fault detection failure occurred for the regulator that powers disk unit
K17.
DISKTRY
BKSPCN
6C21 Disk Unit K18 regulator fault
A fault detection failure occurred for the regulator that powers disk unit
K18.
DISKTRY
BKSPCN
6C22 Disk Unit K19 regulator fault
A fault detection failure occurred for the regulator that powers disk unit
K19.
DISKTRY
BKSPCN
6C23 Disk Unit K20 regulator fault
A fault detection failure occurred for the regulator that powers disk unit
K20.
DISKTRY
BKSPCN
6C24 Disk Unit K21 regulator fault
A fault detection failure occurred for the regulator that powers disk unit
K21.
DISKTRY
BKSPCN
6C25 Disk Unit K22 regulator fault
A fault detection failure occurred for the regulator that powers disk unit
K22.
DISKTRY
BKSPCN
6C26 Disk Unit K23 regulator fault
A fault detection failure occurred for the regulator that powers disk unit
K23.
DISKTRY
BKSPCN
1xxx
System Reference Codes 105

Table of Contents

Other manuals for IBM iSeries 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 800 and is the answer not in the manual?

IBM iSeries 800 Specifications

General IconGeneral
BrandIBM
ModeliSeries 800
CategoryServer
LanguageEnglish

Related product manuals