Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
0856 BPR-1 communication fault MAPPWR
0866 BPR-2 communication fault MAPPWR
0876 BPR-3 communication fault MAPPWR
0D06 BPA 350V power failure MAPPWR
1C06 Cage air flow cooling problem MAPPWR
CE16 BPC-A to BPC-B communication fault
Check cable and connector pins between the two BPCs before replacing
BPCs.
BPCPWR
D216 BPA-A to BPA-B communication fault MAPPWR
D616 UPS utility failure UPSUNIT
D716 UPS battery low condition was detected UPSUNIT
D816 UPS reported a bypass active UPSUNIT
D916 UPS utility power restored UPSUNIT
DA16 UPS installed UPSUNIT
DB16 UPS not available UPSUNIT
DC16 UPS battery low condition was reset UPSUNIT
DD16 UPS reported bypass no longer active UPSUNIT
DF16 UPS failure UPSUNIT
E106 Critical logic overtemperature MAPPWR
E206 Ambient room temperature limit exceeded
F4X6 Hardware configuration cannot support N-mode power
F806, F906, FA06 BPC AC power loss or phase missing MAPPWR
FDB6 BPC Room EPO switch has been detected open MAPPWR
FE06, FE16 BPC UEPO switch is in the bypass position MAPPWR
FE56 BPR-1 communication fault MAPPWR
FE66 BPR-2 communication fault MAPPWR
FE76 BPR-3 communication fault MAPPWR
X115 Processor MDA-1 cable fault MAPPWR
X215 Processor MDA-2 cable fault MAPPWR
X315 Processor MDA-3 cable fault MAPPWR
X415 Processor MDA-4 cable fault MAPPWR
X515 Processor DCA-1 cable fault MAPPWR
X615 Processor DCA-2 cable fault MAPPWR
X715 Processor DCA-3 cable fault MAPPWR
X925 Processor DCA-4 cable fault MAPPWR
XA25 Processor DCA-5 cable fault MAPPWR
XX0X BPA FRU failure not isolated MAPPWR
XX11 BPC fault BPCPWR
XX13 BPC Seeprom VPD fault BPCPWR
XX17 BPF Fan fault BPFPWR
XX21 BPD-1 fault BPDPWR
1xxx