Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
3010 Illegal or unsupported tape unit response
1. Look at the In-use lights. If the green light is off and the yellow light is
on, the tape unit is indicating an error condition.
2. Switch off power to the tape unit.
3. Switch on power to the tape unit.
4. Clean the recording head in the tape unit. Use the IBM Cleaning
Cartridge Kit (part 21F8593).
5. Use a new data cartridge if saving data.
Also see the procedure for reference code FFFF.
91F0914
AJEDA00
3100 IOP to tape unit interface error
1. Ensure that the tape unit is powered on. If the tape unit does not
become powered on, refer to the Maintenance Analysis Procedures in
the 7208 Model 2 8 mm Tape Drive Service Guide, SA23-2640, to analyze
the problem.
2. Switch off power to the tape unit.
3. Reseat the signal cable to the tape unit.
4. Reseat the signal cable to the IOP.
5. Switch on power to the tape unit.
91F0914
FI00141
FI00830
91F0721
42F7300
53F3861
81F9128
AJEDA00
3110 Tape unit command timeout
The tape unit did not complete a command sent by the IOP in the time
allowed.
1. Ensure that the tape unit is powered on. If the tape unit does not
become powered on, refer to the Maintenance Analysis Procedures in
the 7208 Model 2 8 mm Tape Drive Service Guide, SA23-2640, to analyze
the problem.
2. Switch off power to the tape unit.
3. Reseat the signal cable to the tape unit.
4. Reseat the signal cable to the IOP.
5. Switch on power to the tape unit.
91F0914
FI00141
FI00830
91F0721
42F7300
53F3861
81F9128
AJEDA00
FF4D IOP to tape unit interface error; logged only
No action required. This reference code is logged for information only.
FF5D Tape unit response error; logged only
No action required. This reference code is logged for information only.
FFF6 Volume statistics; logged only
No action required. This reference code is logged for information only.
7208
184
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)

Table of Contents

Other manuals for IBM iSeries 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 800 and is the answer not in the manual?

IBM iSeries 800 Specifications

General IconGeneral
BrandIBM
ModeliSeries 800
CategoryServer
LanguageEnglish

Related product manuals