Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
0801 Invalid LID directory detected
During system IPL, the LIDMgr detected an I/O failure or media failure
while trying to read the LID directory.
Perform LIC-PIP8.
FI00070
FI00300
AJDG301
0802 LID directory unusable
During system IPL, the LIDMgr detected that the LID directory and
associated load source is not usable.
Reinstall the Licensed Internal Code using Licensed Internal Code Install
and Restore in the iSeries Service Functions information.
For more information, contact IBM Service Support.
AJDG301
0901 The LinkLoader has found its bad flag ON
This reference code is usually the result of a system termination while the
LinkLoader is performing its work.
Reinstall the Licensed Internal Code using Licensed Internal Code Install
and Restore in the iSeries Service Functions information.
0902 Unable to perform programmed IPL
The LinkLoader was not successful in performing a programmed IPL.
Perform a system IPL. If the problem persists, examine the main storage
dump and determine the reason for the failure of the programmed IPL.
1001 Enqueuing a task to the TDQ which is already enqueued on TDQ
Perform LIC-PIP8.
AJDG301
1103 MISR not readable; must be readable for Normal Mode install
MISR is not readable. Perform a manual install to reinitialize the system.
1104 Failure reading media or not install media
Determine that correct install media is loaded. If correct install media is
installed, media could be corrupt. Obtain another copy of the install media
and reattempt the install. If the install still fails, contact your service
representative.
1201 Critical database segment could not be created
Perform LIC-PIP8.
AJDG301
1204 Error in constraint enforcement
Perform LIC-PIP8.
AJDG301
1210 Object not found in the in-use table
Perform LIC-PIP8.
AJDG301
1215 Error in critical code sequence
Perform LIC-PIP8.
AJDG301
1219 A back leveled driver has been detected
Perform LIC-PIP8.
AJDG301
B6xx (including A6xx)
System Reference Codes 267

Table of Contents

Other manuals for IBM iSeries 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 800 and is the answer not in the manual?

IBM iSeries 800 Specifications

General IconGeneral
BrandIBM
ModeliSeries 800
CategoryServer
LanguageEnglish

Related product manuals