Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
0F2C Unknown box ID
The SPCN node cannot determine the machine type of the box in which it
is installed.
TWRCARD
BACKPLN
21F9429
0F2D Unknown box ID, Code level mismatch.
The SPCN node cannot determine the machine type of the box in which it
is installed.
TWRCARD
BACKPLN
21F9429
0F2E SPCN Network Fault
The box ID is not defined. A network communications failure occurred.
TWRCARD
BACKPLN
21F9429
102B PCC Overcurrent
The power control compartment is causing an over current condition in the
FC 5032 Removable Storage Unit power system.
The ac module and the SPCN port cable should be exchanged together.
TWRCARD
21F5680
21F5793
21F9362
1100 Power Supply P01 error
A fault detection failure occurred for Power Supply P01.
PWRSPLY
ACMODUL
BKSPCN
CBLALL
1101 Power Supply P02 error
A fault detection failure occurred for Power Supply P02.
PWRSPLY
ACMODUL
BKSPCN
CBLALL
1102 Power Supply P03 error
A fault detection failure occurred for Power Supply P03.
PWRSPLY
ACMODUL
BKSPCN
CBLALL
1103 Power Supply P04 error
A fault detection failure occurred for Power Supply P04.
PWRSPLY
ACMODUL
BKSPCN
CBLALL
1104 Power Supply P05 error
A fault detection failure occured for Power Supply P05.
PWRSPLY
ACMODUL
BKSPCN
CBLALL
1105 Power Supply P06 error
A fault detection failure occured for Power Supply P06.
PWRSPLY
ACMODUL
BKSPCN
CBLALL
1108 Regulator R01 error
A fault detection failure occurred for Regulator R01.
PWRREG
BKSPCN
1109 Regulator R02 error
A fault detection failure occurred for Regulator R02.
PWRREG
BKSPCN
110A Regulator R03 error
A fault detection failure occurred for Regulator R03.
PWRREG
BKSPCN
110B Regulator R04 error
A fault has been detected for Regulator R04.
PWRREG
BKSPCN
1xxx
86