Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
9239 Frame Node Fault
An internal error in the SPCN frame node prevents the running of a Frame
command.
TWRCARD
AJDG301
923A ASA Failure
The frame address returned by a secondary node does not match the
address of the frame.
TWRCARD
AJDG301
923B Invalid Packet Length for data sent.
An Invalid Packet Length occurred for data exchanged.
AJDG301
TWRCARD
9280 Response Stack Overflow
Too many responses were received during System Frame command
processing.
CBLALL
AJDG301
TWRCARD
9281 Response Overrun
Response Overrun occurred during System Frame processing.
CBLALL
AJDG301
TWRCARD
9282 No Free Entries
No free entries were found during System Frame processing.
CBLALL
AJDG301
TWRCARD
9283 ARA Failure
An Assign Frame Address Failure occurred during ARA Preprocessing.
TWRCARD
AJDG301
9284 Undefined status
Undefined Status occurred during Frame or STF processing.
TWRCARD
AJDG301
9285 BCC Fault
A BCC Error was detected during Network post processing.
TWRCARD
9286 Length Check Error.
Length Check occurred during SPCN post processing.
TWRCARD
AJDG301
9287 Undefined status
Undefined Status occurred during Command processing.
TWRCARD
AJDG301
9288 Configuration Error
A configuration error was detected during System Frame processing.
TWRCARD
AJDG301
9289 Invalid Packet Length for data sent.
Invalid Packet Length occurred for data exchanged.
AJDG301
TWRCARD
C62E SPCN Network Fault
An SPCN frame-to-frame communication failure was detected.
SRNPU or POSORMU.
TWRCARD
CBLALL
CB15 EEPROM Failure TWRCARD
Table 2. SPCN reference codes for system Models 870 and 890 with table
identifier A0:
For SRCs in this table, where x is a variable number or character, xnnn or xxnn
will appear in the table representing the variable.
1xxx
132
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)