106 Nortel Networks L2/3 Ethernet Switch Module for IBM Eserver BladeCenter
Example 7-20 was tested by being interconnected with Example 7-18 on page 104. The
same parameters for MSTP and VLANs are used. A Cisco 3750 switch is used to connect to
the Nortel GbESM in the BladeCenter chassis.
Example 7-20 Sample MSTP Configuration - Cisco
version 12.2
no service pad
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
!
hostname Switch
!
enable password c
!
no aaa new-model
switch 1 provision ws-c3750-24ts
vtp domain BC
vtp mode transparent
ip subnet-zero
!
no file verify auto
!
spanning-tree mode mst
spanning-tree extend system-id
!
spanning-tree mst configuration
name INTEROP
revision 1
instance 1 vlan 10, 30
instance 2 vlan 20, 40
!
spanning-tree mst 0 priority 12288
spanning-tree mst 1 priority 4096
spanning-tree mst 2 priority 8192
!
vlan internal allocation policy ascending
!
vlan 10,20,30,40
!
!
interface FastEthernet1/0/1
switchport trunk encapsulation dot1q
switchport mode trunk
!
interface FastEthernet1/0/2
shutdown
!
interface FastEthernet1/0/3
shutdown
!
interface FastEthernet1/0/4
shutdown
!
interface FastEthernet1/0/5
shutdown
!
interface FastEthernet1/0/6
shutdown
!

Table of Contents