EasyManua.ls Logo

IBM Nortel Networks L2/3 - Data Collection

IBM Nortel Networks L2/3
190 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 9. Nortel Networks Layer 2/3 GbE Switch Module troubleshooting 159
9.3.2 Data collection
In this particular step, it might be necessary to collect additional information to help isolate
problem cause as noted in the following sections.
Test connectivity
򐂰 Use connectivity testing tools such as ping, traceroute, and Telnet
򐂰 Note error messages that appear
Details from affected users
Ask more detailed questions:
򐂰 Has anything changed recently?
򐂰 How often is the problem occurring?
򐂰 Is the problem readily reproduceable?
򐂰 Is it occurring intermittently or at regular intervals?
Nortel GbESM (Alteon OS) switch dumps
Collect the following dump types:
򐂰 TechSupport dump
/maint/tsdmp
Includes output from the following dumps:
Configuration dump (/cfg/dump)
Information dump (/info/dump)
Statistics dump (/stats/dump)
򐂰 Panic dump
Manually force a panic if switch hangs
/maint/panic
<CTRL-SHIFT-”-”>
/maint/uudmp
Includes a core dump of memory registers
򐂰 Trace buffers
Display switch processor trace buffer contents
/maint/debug/sptb <port#>
Display the management processor trace buffer contents
/maint/debug/tbuf <port#>
Display the snap trace buffer contents
/maint/debug/snap <port#>
Send traces to GbE Technical Support as requested
򐂰 Port diagnostics
Perform a port burn-in test to check for switch port hardware problems. You may also
consider running port diagnostics from maintenance kernel.
Note: If file size != 65 KB, then the panic file is no good.