Specifications — Tower model
Dimensions
Height: 383 mm (15.1 in.)
Width: 192 mm (7.6 in.)
Depth: 378 mm (14.9 in.)
Weight
Minimum configuration as shipped: 8.30
kg (18.3 lb)
Maximum configuration: 10.2 kg (22.5 lb)
Environment
Air temperature:
– System on: 10° to 35°C (50° to 95°F)
– System off: 10° to 43°C (50° to 110°F)
Humidity:
– System on: 8% to 80%
– System off: 8% to 80%
Maximum altitude: 2134 m (7000 ft)
Electrical input
Input voltage:
– Low range:
- Minimum: 90 V ac
- Maximum: 137 V ac
- Input frequency range: 57-63 Hz
- Voltage switch setting: 115 V
– High range:
- Minimum: 180 V ac
- Maximum: 265 V ac
- Input frequency range: 47-53 Hz
- Voltage switch setting: 230 V
– Input kilovolt-amperes (kVA)
(approximately):
- Minimum configuration as
shipped: 0.08 kVA
- Maximum configuration: 0.51
kVA
Note: Power consumption and heat
output vary depending on the
number and type of optional
features installed and the
power-management optional
features in use.
Heat output
Approximate heat output in British
thermal units (Btu) per hour:
– Minimum configuration: 256 Btu/hr
(75 watts)
– Maximum configuration: 706 Btu/hr
(207 watts)
Airflow
Approximately 0.5 cubic meters per
minute (18 cubic feet per minute)
Acoustical noise-emission values
Average sound-pressure levels:
– At operator position:
- Idle: 38 dBA
- Operating: 43 dBA
– At bystander position–1 meter (3.3
ft):
- Idle: 33 dBA
- Operating: 37 dBA
– Declared (upper limit) sound power
levels:
- Idle: 4.8 bels
- Operating: 5.1 bels
Note: These levels were measured in
controlled acoustical environments
according to procedures specified by the
American National Standards Institute
(ANSI) S12.10 and ISO 7779, and are
reported in accordance with ISO 9296.
Actual sound-pressure levels in your
location might exceed the average values
stated because of room reflections and
other nearby noise sources. The declared
sound power levels indicate an upper
limit, below which a large number of
computers will operate.
8 PC 300GL User Guide