Page #37 background imageLoading...
Page #37 background image
Reference
Code
9
36
SVC
Routine
Types
Reference
Notes
all
Type
1
SVC
routines
must
use
the
resident
abnor-
mal
termination
routine
to
terminate
any
task.
The
entry
point
to
the
abnormal
termination
routine
is
in
the
communication
vector
table
(CVT).
The
symbolic
name
of
the
entry
point
is
CVTBTERM.
Type
2,
3,
and
4
SVC
routines
must
use
the
ABEND
macro-instruction
to
terminate
the
current
task,
and
IIiUSt
use
the
resident
abnormal
termination
routine
to
terminate
a
task
other
than
the
current
task.
Before
the
resident
abnormal
is
entered,
the
CPU
must
maskable
interruptions
but
interruption,
and
registers
contain
the
following:
termination
routine
be
masked
for
all
the
machine
check
0,
1,
and
14
must
Register
0
contains
the
address
of
the
TCB
of
the
task
to
be
terminated.
Register
1
contains
the
following
informa-
tion:
Bit
0
is
a 1
if
you
want
a dump
taken.
Bit
1
is
a 1
if
yeu
want
to
terminate
a
job
step.
Bits
2-7
are
zero.
Bits
8-19
contain
the
error
code.
Bits
20-31
are
zero.
Reqister
14
contains
the
return
address.
The
resident
abnormal
termination
routine
exits
by
branching
to
the
address
contained
in
register
14.
The
contents
of
register
15
are
destroyed
by
the
abnormal
termination
routine.

Table of Contents

Other manuals for IBM System/360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System/360 and is the answer not in the manual?

IBM System/360 Specifications

General IconGeneral
BrandIBM
ModelSystem/360
CategoryDesktop
LanguageEnglish

Related product manuals