r----------------------------------T-----------------------------------,
I I
Density
I
I
Value
~-----------------T-----------------~
I I
Model
I
Model
I
I I
2400
I
2400
I
I I
7-track
I
9-track
I
~----------------------------------+-----------------+-----------------~
I 0 I
200
I I
I
1 I
556
I I
I
2 I
800
I
800
I
L
__________________________________
~
_________________
~
_________________
J
If
this
parameter
is
omitted,
the
lowest
density
is
assumed.
TRTCH=value
specifies,
for
7-track
magnetic
tape,
the
tape
recording
technique
as
follows:
Value,
Tape
Recording
Technique
C
Data
conversion
feature
is
available.
E
T
Even
parity
is
used.
assumed.
)
(If
omitted,
odd
parity
is
BCDIC
to
EBCDIC
translation
is
required.
MODE=value
specifies,
for
a
card
reader
or
punch,
the
mode
of
operation.
Either
C
(column
binary
mode)
or
E (EBCDIC
code)
may
be
specified.
STACK=value
specifies,
for
a
card
punch
or
card
reader,
the
stacker
bin
to
receive
cards
as
either
1
or
2.
PRTSP=value
specifies,
for
a
printer,
the
line
spacing
as
either
0,
1,
2,
or
3.
OPEN
--
Initialize
Data
Control
Block
The
OPEN
macro-instruction
initializes
one
or
more
data
blocks
so
that
their
associated
data
sets
can
be
processed.
issue
OPEN
for
all
data
control
blocks
that
are
to
be
used
channel
programs.
Some
of
the
procedures
performed
when
executed
are:
control
You
must
by
your
OPEN
is
Construction
of
data
extent
block
(DEB).
Transfer
of
information
from
DD
statements
and
data
set
labels
to
data
control
block.
Verification
or
creation
of
standard
labels.
Tape
positioning.
Loading
of
programmer-written
appendage
routines.
The
three
parameters
of
the
OPEN
macro-instruction
are:
dcb-addr
90
specifies
the
address
of
the
data
control
block
to
be
initialized.
(More
than
one
data
control
block
may
be
specified.)
specifies
the
intended
method
of
I/O
processing
of
the
data
set.
You may
specify
this
parameter
as
either
INPUT,
RDBACK,
or
OUTPUT.
For
each
of
these,
label
processing
when
OPEN
is
executed
is
as
follows:

Table of Contents

Other manuals for IBM System/360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System/360 and is the answer not in the manual?

IBM System/360 Specifications

General IconGeneral
BrandIBM
ModelSystem/360
CategoryDesktop
LanguageEnglish

Related product manuals