EasyManuals Logo

IBM System/360 System Programmer's Guide

IBM System/360
137 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #88 background imageLoading...
Page #88 background image
EODAD=relexp
specifies
the
address
of
your
end-of-data
routine
is
not
available
when
it
is
abnormally
terminated.
set
routine.
required,
the
If
this
task
is
DSORG=code
specifies
the
data
set
organization
as
one
of
the
following
codes.
Each
code
indicates
that
the
format
of
the
device
dependent
portion
of
the
data
control
block
is
to
be
similar
to
that
generated
for
a
particular
access
method:
Code
DCB
Format
for
PS
QSAM
or
BSAM
PO
BPAM
DA
BDAM
IS
QISAM
or
BISAM
Note:
For
direct-access
devices,
if
you
specify
either
PS
or
PO,
you
must
maintain
the
following
fields
of
the
device
dependent
portion
of
the
data
control
block
so
that
the
system
can
write
a
file
mark
for
output
data
sets:
The
track
balance
(TRBAL)
field,
which
contains
a
2-byte
binary
nuwber
that
indicates
the
remaining
numter
of
bytes
on
the
current
track
The
full
disk
address
(FDAD-MBBCCHHR)
field,
which
indicates
the
location
of
the
current
record.
IOBAD=relexp
specifies
the
address
of
an
input/output
block
(lOB).
If
a
pointer
to
the
current
lOB
is
not
required,
you
may
use
this
field
for
any
purpose.
The
following
parameters
are
not
used
ty
provide
cataloging
information
about
the
data
set.
be
used
later
by
access
method
routines
that
read
set.
RECFM=code
the
EXCP
routines
but
This
information
can
or
update
the
data
specifies
the
record
format
of
the
data
set.
Record
format
codes
are
given
in
the
IBM
System/360
Operating
System:
Control
Program
Services
publication.
BFTEK={SIE}
specifies
the
buffer
technique
as
either
simple
or
exchange.
BFALN={FID}
specifies
the
word
boundary
alignment
of
each
buffer
as
either
full
word
or
double
word.
BUFL=absexp
specifies
t.he
length
in
bytes
of
each
tuffer;
the
maxiwum
length
is
32,767.
BUFNO=absexp
specifies
the
nurober
of
buffers
assigned
to
the
associated
data
set;
the
maximum
number
is
255.
BUFCB=relexp
specifies
the
address
of
a
buffer
pool
control
block,
i.e.,
the
8-byte
field
preceding
the
buffers
in
a
buffer
pool.
Execute
Channel
Program
(EXCP)
Macro-Instruction
87

Table of Contents

Other manuals for IBM System/360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System/360 and is the answer not in the manual?

IBM System/360 Specifications

General IconGeneral
BrandIBM
ModelSystem/360
CategoryDesktop
LanguageEnglish

Related product manuals