Questions and Answers

  • A
    Anthony GillAug 11, 2025
    What to do if the IBO MAGI 2 25-80/180 Water Pump fails to launch?
    • J
      Jill AliAug 11, 2025
      If your IBO Water Pump fails to launch, several factors could be the cause. First, check the installation fuse and replace it if it has tripped. Next, ensure that the overcurrent circuit breaker is on. The pump itself might be damaged, requiring replacement. Also, verify that the voltage is compliant with the supplier's specifications. Finally, a blocked pump rotor can prevent launching, so try unlocking it.
  • R
    richardsonaustinAug 20, 2025
    Why is my IBO MAGI 2 25-80/180 Water Pump operating so loudly?
    • E
      edward51Aug 20, 2025
      If your IBO Water Pump is operating loudly, it could be due to a few reasons. There might be air in the pump, so try venting it. Alternatively, the inflow pressure could be too low, causing cavitation; in this case, increase the inflow pressure at the inlet. Lastly, the pump parameters might be too low. If possible, increase the pump operation mode to a more efficient one; otherwise, consider installing a stronger pump.
  • S
    stevemeyerAug 31, 2025
    How to reduce loud system operation of the IBO MAGI 2 25-80/180?
    • L
      Lindsey SosaSep 1, 2025
      If the IBO Water Pump system is operating loudly, it could be due to air in the installation; try venting the installation. Another potential cause is a flow that is too high; in this case, decrease the inflow pressure at the pump inlet.

IBO MAGI 2 25-80/180 Specifications

General IconGeneral
Voltage230/400 V
Connection size1 1/2 inch
Mounting length180 mm
Frequency50 Hz
Inlet/Outlet Size1 1/2 inch
MaterialCast Iron
TypeCirculating pump
Maximum head8 meters
Max Head8 meters

Related product manuals