Icare TONOVET Plus tonometer instruction manual
ENGLISH
Icare TONOVET Plus tonometer instruction manual ENGLISH
www.tonovet.com
2
www.tonovet.com
3
TONOMETER
Icare® TONOVET Plus
INSTRUCTION MANUAL TV011-002 EN-1.0
The informaon in this document is subject to change without prior noce.
In a conict situaon the English version prevails.
This device complies with:
RoHS Direcve 2011/65/EU
Copyright © 2016 Icare Finland Oy
Made in Finland
Icare Finland Oy/Tiolat Oy
Äyrie 22, FI-01510 Vantaa, Finland
Tel. +358 9 8775 1150, Fax +358 9 728 6670
www.icarenland.com, info@icarenland.com
SAFETY INSTRUCTIONS
WARNING
The tonometer must not come into contact with the paent’s eyes, except for the probes, which may do so for a fracon of a second during measurement.
Do not push the tonometer into the eye (the p of the probe should be 4-8mm, or 5/32 - 5/16 inch, from the eye).
WARNING
The tonometer should only be opened by qualied service personnel. It contains no userserviceable parts, apart from the baeries and a probe base. The Icare
tonometer requires no roune servicing or calibraon other than changing the baeries at least every 12 months and changing or cleaning the probe base.
If servicing is necessary, contact qualied service personnel or your local Icare representave.
WARNING
Never immerse the Icare tonometer, spray, pour or spill liquid onto the Icare tonometer, its accessories, connectors, switches or openings in the chassis.
Dry any liquid on the surface of the tonometer immediately.
WARNING
Use of any accessories other than those specied in the manufacturer’s documentaon, with the excepon of items sold by the manufacturer as replacement
parts for internal components, may result in increased emissions or decreased immunity of the Icare tonometer.
WARNING
Use of any accessory with the Icare tonometer other than those specied may result in increased emissions or decreased immunity of the Icare tonometer.
WARNING
Use only the original and cered probes made by the manufacturer. The probes are for single-use (one per tesng session) only. Use probes taken only from
the intact, original packaging. The manufacturer cannot guarantee sterility of the probe once the seal is compromised. Re-sterilizaon or re-use of the probe
could result in incorrect measurement values, in the breakdown of the probe, cross-contaminaon of bacteria or viruses, and infecon of the eye. Re-sterilizaon
or re-use will void all responsibilies and liabilies of the manufacturer concerning the safety and eecveness of the tonometer.
NOTE
Read this manual carefully, since it contains important informaon on using and servicing the tonometer.
Retain this manual for future use.
If you do not use the tonometer, it will switch o automacally aer 3 minutes.
When you have opened the package, check for any external damage or faults, parcularly for damage to the case. If you suspect that there is something wrong
with the tonometer, contact the manufacturer or distributor.
Use the tonometer only for measuring intraocular pressure. Any other use is improper and the manufacturer cannot be held liable for any damage arising from
improper use, or for the consequences thereof. Use the tonometer only for measuring intraocular pressure of animals.
Never open the casing of the tonometer, except for the baery compartment or to change the probe base.
This manual contains instrucons for replacing baeries and changing the probe base.
Never use the tonometer in wet or damp condions.
The probe base, baery compartment cover, screws, collar and probes are so small that a child or animal could swallow them. Keep the tonometer out of the
reach of children or animals.
Do not use the device if it is broken.
Do not use the device near inammable substances, including inammable anesthec agents.
Prior to each measurement, check that a new disposable probe from an intact package is being used.
Be sure that the probe contains the small plasc round p in front.
Certain microbiological agents (e.g. bacteria) can be transmied from the measuring support. To avoid this, clean the forehead support aer each paent with a
disinfectant, e.g. an alcohol soluon.
The tonometer conforms to EMC requirements (IEC 60101-1-2), but interference may occur in it if used near (<1m) a device (such as a cellular phone) causing
high-intensity electromagnec emissions. Although the tonometers own electromagnec emissions are well below the levels permied by the relevant stan-
dards, they may cause interference in other, nearby devices, e.g. sensive sensors.
If the device is not to be used for a long me, we recommend that you remove its AA baeries, since they may leak. Removing the baeries will not aect the
subsequent funconing of the tonometer.
Be sure to dispose of the single-use probes properly (e.g. in a container for disposable needles), because they may contain micro-organisms from the paent.
Baeries, packaging materials and probe bases must be disposed of according to local regulaons.
No part of the tonometer or probes are made with natural rubber latex.
3
4
4
4
4
5
5
5
5
6
8
8
8
8
8
8
8
8
9
10
11
11
11
12
12
12
12
13
13
13
14
14
14
15
16
TABLE OF CONTENTS
Safety instrucons
Intended use
Introducon
Package Contents
Parts of the tonometer
Installing or changing the baeries
Turning the tonometer on
Loading the probe
Probe base light indicaon
Measurement
Menu funcons
MEASURE – Access to measurement
HISTORY – Old measurements
SOUND – Seng of Tonometer buzzer
LIGHT – Seng of Probe base light
LANGUAGE – Language seng
INFO – Device informaon
Turning the tonometer OFF
Error and info messages
Measurement ow chart
Accessories
Technical informaon
Performance data
Maintenance
Replacing / cleaning the probe base
Cleaning the tonometer
Returning the Icare tonometer for servicing / repair
Periodic Safety Checks
Symbols
Electromagnec declaraon
Guidance and manufacturer’s declaraon
Electromagnec emissions
Electromagnec immunity
Recommended separaon distances between portable and mobile RF communicaons
equipment and Icare TONOVET Plus tonometer
Notes