ENGLISH
12
1. Water condenser
1. Disconnect the machine.
2. Disconnect the water inlet or close the bibb.
3. Disconnect the water inlet and outlet from the condenser.
4. Prepare a solution at the 50% of phosphoric acid and distilled or demineralized water.
5. Make the solution circulate through the condenser. (The solution is more effective if hot – between 35ºC
[95ºF] and 40ºC [104ºF]).
DO NOT USE HYDROCHLORIC ACID.
2. Air Condenser
1. Disconnect the machine.
2. Disconnect the water inlet or close the bibb.
3. Clean the louvered area with the help of an aspirator with a brush, non-metallic brush or low-pressure
air.
3. Cleaning the Stock Container (Compact models)
1. Disconnect the machine, close the water and empty the ice-cube stock.
2. Use a dishcloth and bleach with detergent.
4. Exterior Cleaning
Use the same procedure as the one indicated for the container.
5. Cleaning of the Inlet Filters
They are easily obstructed during the rst days of operation, MAINLY WITH NEW PIPING
INSTALLATIONS.
Loose the hose and clean it under water.
6. Water Leak Control
When working on the machine, always check the water connections, status of the clamps and hoses with
the purpose of avoiding leakages and prevent damages or oods.