Symbol indicates important safety information.
Steps to take if gas odor is detected.
Ensures proper gas supply and connections.
Verifies correct electrical connections and voltage.
Confirms correct venting and air supply.
Verifies clearances, air temp rise, and ducting.
Emphasizes reading all instructions before operation.
Specifies approved gas, location, and garage safety.
Ensures adequate air, proper venting, and filter use.
Conditions for temporary installation during construction.
Details furnace certification and applicable codes.
Guidelines for selecting a suitable furnace location.
Diagram showing clearances for upflow/horizontal models.
Diagram showing clearances for downflow models.
Warnings about placing materials near the furnace.
Importance of proper duct sizing and airflow.
Steps for installing upflow furnace units.
Steps for installing downflow furnace units.
Steps for installing horizontal furnace units.
Ensuring adequate fresh air for combustion.
Explains overtemperature, flame roll-out, and pressure switches.
Specifies air volume for unconfined spaces.
Details air openings for confined spaces.
Requirements for two permanent air openings.
Requirements for a single air opening.
General venting rules and warnings about flue devices.
Precautions for draft inducer vent pipe attachment.
Furnace type and important venting application notes.
Guidelines for installing Type 'B-1' vertical vents.
Rules for terminating vertical gas vents.
Methods for horizontal venting and power venters.
Instructions for inspecting and testing existing vent systems.
Warnings about gas type and conversion kits.
Proper practices for installing gas piping.
Max/min pressures and leak testing precautions.
Steps for LP conversion and NOx insert removal.
Procedure for measuring and setting gas pressure.
Table for natural gas pipe sizing based on capacity.
Table for LP gas pipe sizing based on capacity.
Procedure to verify furnace input rate.
Information on selecting and ordering furnace orifices.
Safety precautions for electrical connections.
Guidelines for thermostat selection and setup.
Notes on electronic air cleaners and humidifiers.
Procedures for connecting multiple furnaces.
Wiring diagram for single-stage twinning.
Wiring diagram for two-stage twinning.
Tables for adjusting orifice size based on altitude.
Alternative derating method for Canada.
Guidance on calculating orifice sizes for altitude.
Orifice sizes for LP gas at different altitudes.
Alternative derating method for Canada.
Steps for safely starting the furnace.
Describes the furnace's automatic start-up sequence.
Steps taken when the furnace fails to ignite.
How to set blower off-delay timings.
Adjusting blower speed for proper airflow.
Procedure for checking air temperature rise.
CFM delivery data for upflow/horizontal models.
CFM delivery data for downflow models.
Explains the high limit control and its causes.
Describes safety switches for roll-out and vent pressure.
Steps for removing the downflow blower assembly.
Notes on motor lubrication and periodic cleaning.
Importance of filters and filter size chart.
Diagrams showing filter placement for return air.
Tips for efficient and safe system operation.
Guidance on periodic furnace inspection and cleaning.
Step-by-step guide for diagnosing IFC issues.
Wiring schematic for UT controls.
Wiring schematic for Invensys controls.