4 - 8
4-4 RECEIVER ADJUSTMENTS
RECEIVER
GAIN
CLARITY
TOTAL GAIN
S-METER
NOISE
BLANKER
ADJUSTMENT
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
POINT
UNIT LOCATION UNIT ADJUST
1
1
1
2
1
2
1
• Display frequency : 2.1820 MHz
• Mode : J3E
• Noise blanker : OFF
• Squelch : OFF
• Speaker : OFF
• AGC : ON
• RF gain : 9
• R223 (MAIN unit) :
Max. clockwise
• R257 (MAIN unit) : Max.counter
clockwise
• R300 (MAIN unit) : Center
Connect a standard signal
generator to the [ANT] connector
and set as:
Frequency : 2.1815 MHz
Level : 0.5 µV
(–113 dBm)
modulation : OFF
• Receiving
While pushing the [SQL] and [CL]
switches, turn power ON.
• Display frequency : 12.2300 MHz
• Mode : J3E
Connect a standard signal
generator to the [ANT] connector
and set as:
Frequency : 12.2315 MHz
Level : 0.32 mV
(–57 dBm)
modulation : OFF
• Receiving
Set the signal generator to OFF (no
output).
While pushing the [SQL] and [T
ONLY] switchs, turn power ON.
• Display frequency : 12.2300 MHz
• Mode : J3E
Connect a standard signal
generator to the [ANT] connector
and set as:
Frequency : 12.2315 MHz
Level : 1 mV
(–47 dBm)
• Receiving
• Display frequency : 12.2300 MHz
• Mode : J3E
Connect a standard signal
generator to the [ANT] connector
and set as:
Frequency : 12.2315 MHz
Level : 3.2 µV
(–97 dBm)
Add the following signal into
the signal generator output.
• Receiving
Muximum output level
1.0 V
–30 dB (32 mV)
Push the [DIMMER]
switch.
7th dot just appears
while pushing the
[DIMMER].
Adjust the maximum
noise wave displayed
on the oscilloscope.
Adjust in
sequence
L74, L75,
L78, L79,
L83, L84,
L85, L92,
L93
[CLARITY]
[VOLUME]
R223
[DIMMER]
Verify
L80, L81
Connect an AC
millivoltmeter to the
[EXT SP] jack with a
4 dummy load.
Connect an AC
millivoltmeter to the
[EXT SP] jack with a
4 ohms dummy load.
S/RF meter
Connect an
oscilloscope to R59.
MAIN
Front
Panel
Front
Panel
MAIN
Font
Panel
MAIN
Rear
Panel
Rear
Panel
Function
display
MAIN
Set the [CLARITY] control to the center position and
push the [DIMMER] switch.
12 3 4
1 msec.
100 msec.
This output level of the standard signal generator (SSG) is indicated as SSG’s open circuit.