428 04 5102 01 August 2012
TECHNICAL SUPPORT MANUAL
Split System Heat Pump
N4H3
DANGER, WARNING, CAUTION, and
NOTE
The signal words DANGER, W ARNING, CAU-
TION, and NOTE are used to identify levels of haz-
ard seriousness. The signal word DANGER is only
used on product labels to signify an immediate haz-
ard. The signal words WARNING, CAUTION, and
NOTE will be used on product labels and through-
out this manual and other manuals that may apply
to the product.
DANGER -- Immediate hazards which will result in
severe personal injury or death.
W ARNING -- Hazards or unsafe practices which
could result in severe personal injury or death.
CAUTION -- Hazards or unsafe practices which
may result in minor personal injury or product or
property damage.
NOTE -- Used to highlight suggestions which will
result in enhanced installation, reliability, or opera-
tion.
Signal Words in Manuals
The signal word WARNING is used throughout this
manual in the following manner:
The signal word CAUTION is used throughout this
manual in the following manner:
Signal Words on Product Labeling
Signal words are used in combination with colors
and/or pictures on product labels.
WARNING
Safety Labeling and Signal Words
!
!
CAUTION
WARNING
TABLE OF CONTENTS
Model Number Identification 2.....................
R--410A Quick Reference Guide 3..................
Wiring Diagrams 4--7.............................
Charging Chart 8.................................
Tech Labels (Expanded Data) 9 -- 16................
Parts List 17 -- 22................................
Exploded Views 23 -- 25..........................
Cooling Multiplying Factors 26 -- 52.................
Heating Multiplying Factors 52 -- 78.................
MODELS
N4H318AKE100 N4H318GKE100
N4H324AKE100 N4H324GKE100
N4H330AKE100 N4H330GKE100
N4H336AKE100 N4H336GKE100
N4H342AKE100 N4H342GKE100
N4H348AKE100 N4H348GKE100
N4H360AKB400 N4H360GKB400
!
WARNING
DEATH, PERSONAL INJURY, AND/OR PROPERTY
DAMAGE HAZARD
Failure to carefully read and follow this warning
could result in equipment malfunction, property
damage, personal injury and/or death.
Installation or repairs made by unqualified per-
sons could result in equipment malfunction, prop-
erty damage, personal injury and/or death.
The information contained in this manual is in-
tended for use by a qualified service technician fa-
miliar with safety procedures and equipped with
the proper tools and test instruments.
Installation must conform with local building
codes and with the National Electrical Code
NFPA70 current edition or Canadian Electrical
Code Part 1 CSA C.22.1.
Question and Answer IconNeed help?

Do you have a question about the ICP N4H324AKE100 and is the answer not in the manual?

ICP N4H324AKE100 Specifications

General IconGeneral
Model NumberN4H324AKE100
CategoryHeat Pump
Refrigerant TypeR-410A
Voltage (V)208/230
Phase1
Cooling Capacity (BTU/h)24000

Summary

Safety Labeling and Signal Words

Signal Word Definitions and Usage

Defines and explains the usage of DANGER, WARNING, CAUTION, and NOTE.

Model Number Identification Guides

Outdoor Unit Model Numbering

Details the meaning of each digit in an outdoor unit model number.

Accessory Part Number Identification

Explains how to interpret accessory part numbers by digit position.

R-410A Quick Reference Guide

R-410A Refrigerant Properties

Provides key information on R-410A refrigerant properties and safe handling.

Connection Diagrams

Outdoor Unit Connection Diagram (Models 18-48)

Illustrates electrical wiring for specific outdoor unit model sizes.

Schematic Diagrams

Outdoor Unit Schematic (Ladder Form 18-48)

Presents the electrical schematic in ladder form for specific model sizes.

Connection Diagram (Model 60)

Model 60 Connection Diagram

Shows the electrical connection diagram for the Model Size 60 unit.

Schematic Diagram (Model 60)

Model 60 Schematic (Ladder Form)

Displays the electrical schematic in ladder form for Model Size 60.

R-410A Charging Chart

R-410A Charging Data

Provides data for charging R-410A systems by liquid line temp/subcooling.

Multiplying Factors

Capacity Adjustment Formulas

Formulas for adjusting system capacity based on indoor temperature.

Parts List - Key Components

N4H3 Major Components

Lists major N4H3 components with part numbers and availability.

Outdoor Unit Exploded View

Outdoor Unit Component Identification

Illustrates the assembly of the outdoor unit with labeled parts.

Control Box Details

H/P Control Box Diagram (208/230V)

Details the internal components and layout of the heat pump control box.

Related product manuals