EasyManuals Logo

ICP N4H342AKE100 User Manual

ICP N4H342AKE100
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
TECHNICAL SUPPORT MANUAL Split System Heat Pump: N4H3
2 428 04 5102 01
OUTDOOR UNIT MODEL NUMBER IDENTIFICATION GUIDE (single phase)
Digit Position: 1 2 3 4 5, 6 7 8 9 10 11 12
Example Part Number:
N 4 H 3 18 G K E 1 0 0
Product Family
4 = R--410A REFRIGERANT
A = Air Conditioner
H = Heat Pump TYPE
3 = 13 SEER
4 = 14 SEER
5 = 15 SEER NOMINAL EFFICIENCY
18 = 18,000 BTUH = 1½ tons
24 = 24,000 BTUH = 2 tons
30 = 30,000 BTUH = 2½ tons
36 = 36,000 BTUH = 3 tons
42 = 42,000 BTUH = 3½ tons
48 = 48,000 BTUH = 4 tons
60 = 60,000 BTUH = 5 tons NOMINAL CAPACITY
A = Standard Grille
G = Coil Guard Grille
C = Coastal FEATURES
K = 208/230--1--60 VOLTAGE
Sales Code
Engineering Revision
Extra Digit
Extra Digit
ACCESSORIES PART NUMBER IDENTIFICATION GUIDE
Digit Position: 1 2 3 4 5 6, 7 8, 9 10, 11
Example Part Number:
N A S A 0 01 01 CH
N = Non--Branded BRANDING
A = Accessory PRODUCT GROUP
S = Split System (AC & HP) KIT USAGE
A = Original
B = 2nd Generation MAJOR SERIES
0 = Generic or Not Applicable
2=R--22
4 = R--410A REFRIGERANT
Product Identifier Number
Package Quantity
T ype of Kit(Example: CH = Crankcase Heater)