CONTROL OF WATER TEMPERATURE AND SYSTEM TYPES
The water temperatures and system types are factory preset but may be adjusted. The following settings can be changed.
1. DHW Temperature (optional)
2. DHW System
3. CH System
4. Flow Temperature
P A R A
Press Display
DHW Temperature (Optional)
o
C
Instant water heater 40 65
Storage Tank 20 70 60
Press Display
Factory
Setting
Upper
Limit
Lower
Limit
Description
DHW System 00 = Off 01
01 = On
02 = Off + pump continuous
03 = On + pump continuous
1. 6 0
2. 0 1
CH System 00 = Off
01 = On 01
02 = Off + pump continuous
03 = On + pump continuous
3. 0 1
CH Flow Temperature
o
C 20 90 82
4. 8 2
Press the 'step' button until the desired parameter is displayed.
Press the '+' or '-' buttons to change the values.
The parameter setting can be stored by pressing and releasing the 'store' button, the new setting ashes twice to show it has been
accepted. The new setting will become active when the 'mode' button is pressed several times or if the display is left. If the display
is left, after 20 minutes it automatically returns to 'standby' mode.
Parameter settings and limits are listed below.
Parameter mode is entered from standby mode by pressing the 'mode' button once.
4