BREAKDOWN REASONS & REMOVING
Breakdown Condition Breakdown Reasons Resolution
R.O. Systems not running
1. Water stopping or water
pressure too low
2. No power
3. Other reason unknown
- Check feeding switch on.
- Check switch of water tank
on.
- Check power.
- Remove the plug of power
if water stopping.
- Please, send purifier to
repair for the reasons
unknown.
Leakage
Connector loosen or bad
installation.
Off feeding switch, remove
power plug, loosen the
connector, then, install and
lock tightly again.
The water is full in tank, but
no water out
Pressure tank breakdown
(pressure losing)
Fill the air from tank side’s
connector, drain away the
water, remove pressure
water tank switch to fill air
(press about 0,4 bar).
Purify water less or no water
out
Four sides valve breakdown
Off feeding switch, remove
power plug, change filter,
then on the purifier, please
see Installation: step by
step”.
Water tank filled, waste
water draining continuously
Four sides valve break down
Change four sides valve,
and send the purifier to
repair.
(This problem must resolve
by professional technician).
Purifying the water
continuously
1. High pressure breakdown
2. Check valve breakdown
3. Pump loses pressure
4. Four sides valve clogged.
Remove power plug and
send the purifier to repair.
(This problem must resolve
by professional technician).