Page #6 background image
Instruction Manual
Innovative DisplayWorks
MAINTENANCE
Cleaning
Before cleaning the appliance, always remember to unplug it.
Unplug the cooler at the electrical outlet; never pull the service cord.
Do not use sharp or pointed objects for cleaning.
Clean the inside cabinet of the cooler with a clean damp cloth. Avoid damage by using non-abrasive and non-
ammable cleaning products.
Clean the condenser at least once a month with a vacuum cleaner or a brush to
eliminate the dust accumulation.
Light Replacement
Unplug the cooler before removing the LED light strip.
Remove the screws.
Remove the light cover gently.
Take out the LED light strip.
Replace the used strip with new equivalent light strip.
Install the light cover and tighten the screws.
Plug in the cooler.
Power Failure
Please minimize the frequency of opening the door during a power failure.
If your cooler is unused for an extended period of time, unplug, empty, and clean your cooler and keep the door open
to avoid condensation, formation of mold, or odors.
Moving The Cooler
Empty the unit.
Secure all loose parts inside the cooler.
Tape the door shut.
During transportation, make sure that the cooler is in an upright position.
Drip pan
During normal compressor cycle, water will drain into the drain pan and evaporate.
To clean, gently pull the drain pan towards you and remove. Slowly reinstall it after cleaning.
TROUBLESHOOTING
If your cooler is not working properly:
Check the electrical outlet for power, and that the plug is properly inserted.
Check to see if the circuit breaker is tripped or the fuse is blown.
Check the condenser for proper cleaning.
If your cooler is making noise:
Check that the cooler is level and on a at surface.
If the compressor turns on and off frequently:
The room temperature is higher than normal.
The door is not closed completely.
The door gasket is not sealed well.
There is insuf cient clearance around the cooler.
The temperature is not set properly.
The cycling frequency will reduce when all of the cans reach the set temperature.
The following is not a malfunction:
It is normal to hear gurgling sounds caused by the ow of refrigerant when each cooling cycle ends.
REFRIGERANT
The cooler utilizes R600a refrigerant.
SPECIFICATIONS
Model:
Power Supply (V/Hz):
Dimension (W x D x H):
Box Dimension (W x D x H):
Maximum Load Per Shelf:
NSF-7 Standard:
This equipment is intended for the storage and display of non-potentially
hazardous bottled or canned products only.