Please keep this booklet for future reference.
Installer, when you have read these instructions
please ensure you leave them with the user.
Electric Showers
Installation
Instructions
& User Guide
eco
2 Year Guarantee
Thermostatic Electric
Shower

Questions and Answers:

iflo Thirle Electric Shower 8.5 Kw Specifications

General IconGeneral
Brandiflo
ModelThirle Electric Shower 8.5 Kw
CategoryPlumbing Product
LanguageEnglish

Summary

Important Safety Information

Electrical Requirements

Earthing Requirement

Appliance and connecting metal pipework must be earthed.

Electrical Safety Precautions

Switch off power, isolate circuit, verify earth before connections.

Power Supply Specification

Connect only to a 230-240V AC supply.

Dedicated Electrical Supply

Must be connected to its own independent electrical supply.

Consumer Unit Requirements

Ensure adequate fuse way rating or consult electrician.

Cable and Switch Requirements

Use 45 Amp double pole switch with minimum 3mm contact separation.

Residual Current Device (RCD) Requirement

Must incorporate a 30mA RCD for earth leakage protection.

Circuit Protection Devices

Use MCB or Cartridge Fuse, not rewireable fuses.

Earth Impedance Measurement

Neutral and Earth impedance must be less than 1.0 Ohms.

Water Requirements

Freeze Protection Warning

Do not install in areas subject to freezing conditions.

Minimum Water Supply Pressure

Requires minimum 0.07MPa (0.7bar) and 8 L/min flow rate.

Maximum Static Inlet Pressure

Maximum static inlet pressure must not exceed 1.0MPa (10bar).

Recommended Thermostatic Pressure

0.1MPa (1bar) and 8 L/min recommended for full thermostatic performance.

Fixing Your Shower to the Wall

Surface Mounting Requirement

Fit unit to flat, waterproof surface, not tiled up to edges.

Recessing and Sealing Prohibition

Do not recess or seal unit around edges to allow air circulation.

Plumbing Connections

Outlet Vent Prohibition

Outlet must not be blocked or connected to other devices.

Mandatory Stop Valve

Fit independent stop valve for servicing and maintenance.

PRD Triggering Warning

Avoid damaged hose/handset to prevent PRD activation.

PRD Activation Procedure

If PRD activates, switch off supplies and contact point of purchase.

Electrical Connections

Earthing All Metal Components

Appliance and connecting metal pipework must be earthed.

Earth Continuity Conductor

Connect earth continuity conductor to exposed metal parts.

Terminal Block Connection

Connect Earth, Neutral, and Live cables to correct terminals.

Terminal Tightness Importance

Ensure terminals are fully tightened for metal-to-metal contact.

Power On Safety Warning

Do not switch on power until cover and cable connection are fitted.

Fitting Your Riser Rail to the Wall

Pre-Drilling Wall Check

Check for hidden pipes and cables before drilling walls.

Commissioning - Testing the System

Pre-Use Final Flush

Flush shower unit and hose to remove debris before first use.

Initial Control Settings

Set power control to cold; temperature control to minimum flow.

System Flushing Procedure

Press START/STOP, wait for water flow, adjust temp control to flush.

Low Pressure Indicator (LP)

'LP' indicates low pressure; switch off and check pressure.

Operating the Shower

Child Supervision Warning

Children must be supervised to ensure they do not play with appliance.

Troubleshooting

No Water Flow Troubleshooting

Check isolating valve, filter, power supply, and outlet hose.

Water Temperature Too Hot Troubleshooting

Check water flow, adjust temperature control, reduce power setting.

Hot and Cold Cycling Troubleshooting

Check water pressure, wait for increase, adjust temperature control.

PRD Outlet Water Troubleshooting

Check for obstruction in hose or handset; contact point of purchase.

'LP' Indicator Troubleshooting

Indicates low pressure; turn off unit and wait for pressure to increase.

Error Code 'E1' Troubleshooting

Indicates thermistor fault; contact point of purchase.