41
Boiler fire in
self off and / or
the boiler stops
automatically.
The pellet hopper is empty
Fill the pellet hopper.
Pellet feeder does not work.
The pellet temperature
Close the door or replace with original spare parts.
Change to a type of pellet recommended by the
manufacturer.
Have you checked the fuel supply rate by the technical
service.
Guide to clear the combustion chamber as
indicated.
Clean the smoke duct.
Check if smoke duct is blocked.
sensor is malfunctioning
The door is not fully closed
Unsuitable pellets.
Low pellet ratio
Combustion chamber dirty.
Smoke outlet obstructed
Pressure switch cuts.Smoke extraction
motor failed.
Boiler does not
work.
Electrical failure or lack of
Make sure that the main switch in work position
The fuse has blown.
Change this fuse
Broken pressure switch
Change the pressure switch
passage of smoke out of the air or air ducts
disabled
Clean the smoke outlet and / or smoke duct.