Procedure for powering up the ID5001P unit from external supply or batteries.
How the unit operates in listening mode, monitoring acoustic energy for pig passage.
Details on how the unit detects a pig passage and signals the event.
Explanation of the simplified flowchart for the ID5001P detection algorithm.
Guide to navigating and operating the ID5001P through its single-button menu system.
Entry point to the menu system, detailing options like Date, Time, Events, and System Info.
Functionality for viewing and erasing stored event data within the unit's memory.
Accessing read-only system parameters such as serial number, firmware, and battery status.
Using diagnostic screens to view live signals for debugging and parameter adjustment.
Configuring the unit's output functionality, including delay, relay, and current loop settings.
Adjusting detection parameters like thresholds, timing, and averaging for accurate pig detection.
Communication protocol and configuration for the RS485 serial interface.
Map of registers for accessing and controlling the ID5001P via MODBUS RTU protocol.
Details on using the mounting plate for attaching the main housing to pipelines, posts, or walls.
Procedure for mounting the main housing onto a post using the provided assembly.
Instructions for mounting the main housing onto a pipeline using ratchet straps or banding.
Guide for securely attaching the sensor unit to the pipeline.
Instructions for installing a sunshade on a post-mounted unit.
Instructions for installing a sunshade on a pipeline-mounted unit.
Step-by-step guide on how to safely open the unit's housing.
Procedure for properly closing and securing the unit's housing.
Detailed instructions for safely removing and replacing the unit's batteries.
Overview of accessing and making external electrical connections to the unit.
Information on the DPDT relay output contacts and their behaviour in different states.
Details on reserved EX connections, noting they are not for current use.
Information on the RS485 interface for remote signalling and interaction.
Guidelines for connecting the OV reference for noise immunity.
Instructions for connecting the enclosure for electrical and equipotential bonding.
Information regarding the TRIG+/- connections and their isolation.
Details on the connection of the local control button.
Explanation of the current loop output for remote signalling and its behaviour.
Note regarding the internal battery connection, not for external use.
How to connect the external 24VDC power supply to the unit.
Steps for installing the ID5001P configuration software and its prerequisites.
Instructions for installing the required Microsoft .NET Framework.
Detailed steps to install the ID5001P configuration software on a PC.
Guidance on operating the ID5001P Config Software, including warnings.
Configuration of COM port, baud rate, and slave address for software communication.
Using the tab to read and write numerical parameters to the unit.
Viewing read-only parameters like detection status and sensor values.
Configuring boolean parameters such as logging and LED flash settings.
Viewing and downloading logged PIG event data from the unit.
Monitoring sensor readings in real-time graphically.
Graphically viewing stored PIG event data.