ENGLISH 15
ignite immediately and will seem to
blow’s lightly when they do ignite, this is
usually due to air in the gas pipe which
should clear itself within seconds of
operation.
10. If after following the instructions given,
satisfactory performance cannot be
obtained, contact the local gas authority
for advice and assistance.
Before leaving - Check all connections for
gas leaks with soap and water. Ignite all
burners to ensure correct operation of gas
valves, burners and ignition. Turn gas taps
to low ame position and observe stability
of the ame. In case the appliance fails to
operate correctly after all checks have been
carried out, refer to the authorised service
provider in your area.
Adjustmenttodifferenttypeofgas
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualied persons in order
to avoid a hazard.
WARNING
- This operation must be performed by a
qualied technician.
If the appliance is intended to operate with
a different gas from the gas type stated on
the rating plate and information label on the
top of the hob, change the injectors.
Remove the information label and keep it
with the instructions booklet.
Use pressure regulators suitable for the gas
pressure indicated in the Instruction.
- The gas nozzles must be changed
by After Sales Service or a qualied
technician.
- Nozzles not supplied with the appliance
must be ordered from After Sales
Service.
- Adjust the minimum setting of the taps.
NOTE: when liquid petroleum gas is used,
the minimum gas setting screw must be
tightened as far as it will go.
IMPORTANT: should you experience
difculty in turning the burners knobs,
please contact the After Sales Service for the
replacement of the burner tap if found to be
faulty.
Replacingtheinjectors(seeparagraph
“injectortable”)
- Remove grids (A).
- Extract burners (B).
- Using a socket spanner of the
appropriate size unscrew the injector (C),
unscrew the injector to be replaced.
- Replace it with the injector suitable for
the new type of gas.
- Re-assemble the injector in (D).
Before installing the hob, remember to afx
the gas calibration plate supplied with
the injectors in such a way that it covers
the existing information relating to gas
calibration.
B
B
A
D
C