32
EN
Do not use with water that is
microbiologically unsafe or of unknown
quality without adequate disinfection before
or after the system. Systems certied for
cyst reduction may be used on disinfected
waters that may contain lterable cysts.
Test & certication results:
• Rated Capacity - 125 gallons/473
liters for the ice and water lter
• Rated service ow - .65 gallons per
minute
• Operating Temp: Min. 33°F, Max.
100°F
• Maximum Rated Pressure - 100
pounds per square inch
• Recommended Minimum Operating
Pressure: 30 pounds per square inch
To replace your water lter:
It is not necessary to turn the water
supply off to change the lter. Be ready
to wipe up any small amounts of water
released during the lter replacement.
1 Turn Off the ice maker power switch.
2 Remove the old lter by rotating it
counter-clockwise (to the left) 90
degrees to release it.
3 Slide the old lter cartridge straight
out of the housing and discard it.
4 Unpackage the new lter cartridge.
Slide it into the lter housing as far as
it will go with the grip end horizontal.
5 Push lightly inward on the lter while
rotating it clockwise (to the right). The
lter will then pull itself inward as it is
rotated. Rotate the lter 90 degrees
until it stops and the grip end is
vertical. You may be able to feel a very
light click as the lter locks into place.
6 Press a drinking glass against the
water dispenser while checking for
any leaks at the lter housing. Any
spurts and sputters that occur as
the system purges air out of the
dispenser system are normal.
The ice and water lter
system is tested and certied
to NSF/ANSI Standards 43,
53 and 401 for the reduction
of claims specied on the
performance data sheet.
More about your Advanced
Water Filter
FILTER REPLACEMENT
7 Continue dispensing water for 3-4
minutes or until 1.5 gallons of water
has owed through the system. You
will likely need to empty and rell
your glass several times.
8 Turn On the ice maker.
9 Press and hold the Water Filter reset
button on the control panel for three
seconds. When the display changes
from Red to Green, the status has