INTERNATIONAL MACHIINE CONCEPTS
conduct the sealing process test, to identify the optimum process
parameters and make records. After debugging is done, prevent
accidental changes in the normal production. Also conduct regular
sampling, to avoid sealing of the substandard products.
6.6 When the operating current is excessive, the machine’s over-current
protection function is activated, and the conveyor belt automatically
stops working. At this time, appropriately pull up the spacing between
sensor head and sealed object, to reduce the operating current. After
adjustment, re-boot the machine to proceed with the sealing operation.
6.7 When the temperature of main circuit of the equipment is excessively
high, the thermal overload protection function is activated, and the
equipment automatically stops working. After the temperature drops
to the normal state, the equipment will automatically start the sealing
operation.
7. Maintenance and repair
7.1 The machine is electromechanical integration equipment. In order to
avoid the equipment appliance from premature aging and damage, the
working environment must remain clean and dry. Also, it is
prohibited to use the machine in environment of high humidity, high
corrosion, and high dust.
7.2 The instrument switches on the operator control panel shall not be
immersed with water or other liquids, so as not to cause damage or
leakage. During operation, do not use excessive force, so as to extend
the service life.
7.3 The transmission part should be often added with the proper amount
of lubricants, and no phenomena of blockade or serious friction
should exist.
7.4 The sensor head and the electrical appliance in the chassis have
high-voltage electricity. The untrained professional electrician shall
not open the sensor head and the back cover of the electrical box, to
avoid electric shock accidents.