INSTALLATION
For the Installer
These Instructions contain important information designed to help the user
obtain the maximum benefit from their investment in an IMC VR60 Glass
Froster.
Please read them carefully before starting work, and consult with the supplier in
the event of any queries.
Be sure to leave this Instruction Manual with the user after installation of the
machine is complete.
Procedure
WARNING
The following table shows the weight and the minimum quantity of
people required to lift each unit:
Glass Froster Net Weight
Quantity of
People
MR60 (all variants) 57.5 kg (max) 2
Install the unit on a flat and level floor.
Ensure a minimum 10mm clearance to either side of the unit, there is to be
a 20mm clearance at the top and 60mm clearance at the back.
Do not install the unit close to a heat source such as a radiator or a warm air
outlet.
Ensure that the unit is standing level by adjusting the feet on the base of the
unit.
The unit has an automatic defrost cycle and evaporates all the condensate
water without the need for a drainage system.
NOTE!
It is important to install the Glass Froster on a flat surface. This
ensures that the doors are level. Adjustment is provided via the
feet, to enable the installer to level the cabinet. Engineer Call-
outs in order to level Glass Frosters, will not be covered under
warranty.