Setpoint Zone Menu
Menu item Description Range
Customised
value
Set ow Flow setpoint of the zone 5 ÷ 80 °C
Oset Flow oset of the zone -15 ÷ 15 °C
Setpoint DHW Menu
Menu item Description Range
Customised
value
Set Comfort Setpoint DHW in Comfort mode 20 ÷ 65 °C
Set Economy Setpoint DHW in Economy mode 10 ÷ 65 °C
Set Manual Setpoint DHW Manual 10 ÷ 65 °C
DHW Temperature Temperature read by DHW probe 10 ÷ 65 °C
Time program Enable Enabling DHW time slots
MAN /
AUTO
Antilegio function Enabling Antilegio function
OFF / 24h