InBody170 USERS MANUAL
Thank you for purchasing the InBody170.
Please read manual prior to use and operate with care. Make sure to keep this manual for future reference.
Question and Answer IconNeed help?

Do you have a question about the inbody 170 and is the answer not in the manual?

Summary

How to Use This Manual

Understanding Safety Symbols

Explains the meaning of Warning, Caution, and Note symbols for safe operation.

Safety Information

Device Compatibility and User Restrictions

Incompatible medical devices and advice for disabled persons or children.

Electrical Safety and Handling

Proper grounding, power cord handling, and avoiding electric shock.

Equipment Tampering and Health Advice

Warnings against dismantling, using on pregnant women, and self-diagnosis.

Hygiene and Cross-Contamination Prevention

Procedures for cleaning the foot plate to prevent disease transmission.

Installation and Handling Precautions

Guidelines for floor installation, AC adapter use, and handling moving parts.

Operational and Environmental Safety

Recommended environmental limits and adherence to product standards.

Indicators and Safety Symbols

Device Indicators and Ports

Identifies the Serial Port, USB Port, and other device indicators.

Safety Symbols Explained

Explains various safety symbols used in the manual and on the device.

Electronic Waste Disposal Guidelines

Instructions for the proper disposal of electrical and electronic equipment.

Workplace Requirements

Operation Environment Specifications

Specifies the required temperature, humidity, and atmospheric pressure for operation.

Transport and Storage Conditions

Outlines temperature, humidity, and pressure limits for transport and storage.

Adapter Power Specifications

Details the power input and output requirements for the device adapter.

Chapter 1: Installation & Maintenance

Contents of the Box

Lists all items included in the InBody170 package upon purchase.

Exterior and Functions Overview

Provides an identification of the main physical parts of the InBody170.

Operation Part Description

Details the head unit's LCD, keypad, speaker, and electrode connections.

Stand Part Description

Details the stand assembly, including electrode holders and thumb electrodes.

Base Part Description

Explains the base components like sole electrodes, foot plate, and leveling features.

Rear Part Description

Covers the rear panel, specifically the back cover and its access restrictions.

Summary

How to Use This Manual

Understanding Safety Symbols

Explains the meaning of Warning, Caution, and Note symbols for safe operation.

Safety Information

Device Compatibility and User Restrictions

Incompatible medical devices and advice for disabled persons or children.

Electrical Safety and Handling

Proper grounding, power cord handling, and avoiding electric shock.

Equipment Tampering and Health Advice

Warnings against dismantling, using on pregnant women, and self-diagnosis.

Hygiene and Cross-Contamination Prevention

Procedures for cleaning the foot plate to prevent disease transmission.

Installation and Handling Precautions

Guidelines for floor installation, AC adapter use, and handling moving parts.

Operational and Environmental Safety

Recommended environmental limits and adherence to product standards.

Indicators and Safety Symbols

Device Indicators and Ports

Identifies the Serial Port, USB Port, and other device indicators.

Safety Symbols Explained

Explains various safety symbols used in the manual and on the device.

Electronic Waste Disposal Guidelines

Instructions for the proper disposal of electrical and electronic equipment.

Workplace Requirements

Operation Environment Specifications

Specifies the required temperature, humidity, and atmospheric pressure for operation.

Transport and Storage Conditions

Outlines temperature, humidity, and pressure limits for transport and storage.

Adapter Power Specifications

Details the power input and output requirements for the device adapter.

Chapter 1: Installation & Maintenance

Contents of the Box

Lists all items included in the InBody170 package upon purchase.

Exterior and Functions Overview

Provides an identification of the main physical parts of the InBody170.

Operation Part Description

Details the head unit's LCD, keypad, speaker, and electrode connections.

Stand Part Description

Details the stand assembly, including electrode holders and thumb electrodes.

Base Part Description

Explains the base components like sole electrodes, foot plate, and leveling features.

Rear Part Description

Covers the rear panel, specifically the back cover and its access restrictions.

Overview

The InBody170 is a body composition analyzer designed to quantify and measure the four major components of the body: water, protein, minerals, and fat. It aims to provide accurate and reproducible results through direct segmental measurement, evaluating the effectiveness of diet control and exercise prescriptions without relying on empirical estimations. The device is intended for use in health care settings to help achieve a balanced body composition, moving beyond traditional obesity diagnoses based solely on appearance.

Function Description

The InBody170 operates by analyzing body composition, which involves measuring the impedance of different body segments. The device features a head unit with an LCD screen and a keypad, a stand, and a base with foot electrodes. The LCD displays the analysis procedure, messages, and results, guiding the user through the measurement process. The keypad, consisting of 19 buttons, allows for data input, setting up the operating environment, and printing test results. A speaker provides audio signals to inform users of the measurement status.

The stand part includes hand electrode holders and the hand electrodes themselves. Each hand electrode incorporates a thumb electrode and a palm electrode. The thumb electrode is activated by contact with the thumb, while the palm electrode is activated by wrapping the palm around it. These electrodes facilitate the flow of electrical current through the body during measurement. The hand electrode cable connects these electrodes to the internal circuitry, transferring voltage and electric current for analysis.

The base part features front and rear sole electrodes, a foot plate, a joint cover, a joint screw, a bubble level indicator, and level screws. The front sole electrode is activated by placing the forefoot directly on it, and the rear sole electrode by placing the heel. These electrodes enable current flow through the lower body. The foot plate houses the load cell, which measures body weight. The joint cover protects the joint mechanism when the stand is folded, and the joint screw fixes the upper part of the device. The bubble level indicator helps ensure the device is level for accurate measurements, and the four level screws allow for manual adjustment of the device's balance.

Usage Features

To use the InBody170, individuals stand on the foot plate, ensuring proper contact with the sole electrodes, and grasp the hand electrodes. The device then performs a direct segmental measurement, which is crucial for its high accuracy. The user interface is designed to be intuitive, with clear instructions displayed on the LCD and a keypad for easy data entry and function selection.

The device is designed for use by individuals who can stand unassisted. Physically disabled persons or children require assistance to ensure accurate results and prevent injury. It is important to maintain a proper posture during measurement and avoid movement to ensure accurate test results.

Maintenance Features

The InBody170 requires specific maintenance to ensure its longevity and accuracy. The foot plate, which comes into direct contact with users, must be cleaned with an appropriate disinfectant after each use to prevent cross-contamination. A soft cloth and ethyl alcohol are recommended for wiping the foot plate, and strong chemicals should be avoided. Liquids should never be poured directly onto the foot plate, as this can cause internal damage.

The device should be installed on a flat and stable floor, and the bubble level indicator should be used to ensure it is properly leveled using the adjustable level screws. This prevents incorrect measurements and potential harm.

For transportation, it is crucial to use the original packing material and shipping box to protect the equipment from physical shock or damage. The wrapping material should be saved for future relocation needs.

The InBody170 is designed with internal parts that are not user-serviceable. Dismantling the equipment or opening the back cover voids the warranty and may result in service charges. Any repair or examination should be conducted only by Biospace's professional A/S staff. In case of device quality or operation problems, users are advised to contact the manufacturer or distributor.

The device should be operated within specific environmental conditions: a temperature range of 10-40 ℃ (50-104°F), relative humidity of 30-75%, and atmospheric pressure of 70-106 kPa. Extreme temperatures, humidity, or pressure can affect operation and cause errors.

The InBody170 uses a specific AC adapter (12V, 3.4A) provided by Biospace. Using other adapters may cause malfunction. Care must be taken to prevent spills of food or beverages on the product, as this can seriously damage electronic components. Excessive force on the hand electrode cable should be avoided to prevent damage to the product.

The device complies with international safety and quality standards, including IEC60601-1 (EN60601-1) for safety of electric medical equipment, and IEC60601-1-2 (EN60601-1-2) for electromagnetic compatibility. It is manufactured under the full quality assurance system of ISO 90001 and ISO 13485.

Local governing ordinances and recycling plans for device components, including batteries, should be followed for disposal. The device should not be treated as household waste but handed over to an applicable collection point for recycling electrical and electronic equipment.

inbody 170 Specifications

General IconGeneral
TypeBioelectrical Impedance Analysis (BIA)
Body Composition AnalysisYes
Weight MeasurementYes
Muscle Mass AnalysisYes
Body Fat PercentageYes
Basal Metabolic Rate (BMR)Yes
Total Body Water (TBW)Yes
Impedance MeasurementYes
Measurement MethodBioelectrical Impedance
Weight Measurement Range10 kg - 250 kg
Height Measurement Range90 cm - 220 cm
Body Fat Percentage Measurement Range5% - 75%
Data OutputUSB
Power SupplyAC 100-240V, 50/60Hz
Measurement TimeApprox. 15 seconds
Segmental AnalysisYes
DisplayLCD

Related product manuals