ENGLISH
41
ON OFF
PRESET PROGRAMS FOR KD
PROGRAM WORKING TIME AMBIENT TEMPERATURE
1ST CYCLE 2ND CYCLE
P1
09-14 17-22 ≤ 25°C
P2
08-14 17-23 ≤ 28°C
P3
07-14 17-23 ≤ 30°C
P4
adjustable
OFF
switch ON/o
TIMER OPERATION METHOD: USE
The Minibars of the K Ecosmart series are equipped with a pre-set thermostat located on the
back of the refrigerator (the temperature has already been adjusted to the correct operating
levels). You can select the duration of the cooling cycles using the remote control. When the
Minibar is connected to power supply, it automatically turns on using the mechanical thermostat
functions.
OPERATING CYCLES OF K ECOSMART COMPRESSOR UNIT CONTROLLED BY THE
ELECTRONIC TIMER
The compressor is in operation to cool
the contents of Minibar and to freeze
the eutectic plate (6 hours over 24 hour
are sucient).
The compressor is O and the cool-
ing energy stored in the holding
plate maintains the inside Minibar
temperature. The Minibar is com-
pletely noiseless during the night.