EasyManua.ls Logo

Index KNIGHT MPL-1000 PLUS User Manual

Default Icon
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Page 1 of 8 0900820 (draft 04/00)
03/3/86
,16758&7,210$18$/
The new MPL-1000 PLUS is designed to meet today’s laundry chemical injection needs with economy and greater
flexibility in mind. Through advanced microprocessor technology, the MPL-1000 PLUS is one of Knight Equipment’s
least expensive laundry injectors, yet has all of the required features to meet every type of washroom condition. The
MPL-1000 PLUS can run up to 6 pump outputs in any one of three different modes; SIGNAL, SEQUENCE, and
RELAY mode. L.E.D indicators let the user know whether they are programming in SIGNAL or SEQUENCE mode,
what is being programmed, the mode the MPL-1000 PLUS is running in, and which pump is being signaled. The
MPL-1000 PLUS has dual formula capability for light or heavy soil conditions for each pump, with separately
programmable delay times for each formula. Innovative use of delay times allows calibration to be a one-man job. All
programmed times are stored in a non-volatile memory which cannot be altered by voltage spikes or power outages.
All signal inputs have independent signal and common connections, allowing multi-washer connections to one circuit
board. The signal input circuitry will accept and verify a signal anywhere between 18 to 240 volts (AC or DC).
When connecting signal wires to the MPL-1000 PLUS, always check the schematic of the washmachine. If in doubt
about the installation, please contact your nearest authorized Knight representative or contact the machine
manufacturer at the number listed below.
MACHINE DESCRIPTION CITY/STATE PHONE
American Amer. Laundry Machinery Cincinnati, OH (503) 731-5500
Braun G.A. Braun, Inc. Syracuse, NY (315) 475-3123
Cascadex Amer. Laundry Machinery Cincinnati, OH (503) 731-5500
Cook Cook Machinery Co. Dallas, TX (214) 421-2153
Dyna Wash Edro Corporation E. Berlin, CT (203) 828-0311
Hammond Washmaster Systems Memphis, TN (901) 362-0023
Huebsch McGraw Edison Co. Cincinnati, OH (503) 351-6510
Inn House Wascomat of America Inwood, NY (516) 371-4400
Milnor Pellerin Milnor Corp. Kenner, LA (504) 467-9591
Schulthess Schulthess Machinery Bethesda, MD (301) 656-9308
Speed Queen Ametek Grand Prarie, TX (214) 647-2626
Troy Ametek Grand Prarie, TX (214) 647-2626
Uniwash Unimac Company Marianna, FL (904) 526-3405
Washex Washex Machinery Co. Wichita Falls, TX (817) 855-3990
Wascomat Wascomat of America Inwood, NY (516) 371-4400
Zanussi Zanussi Corporation New York, NY (212) 532-5494
VOLTAGE INFORMATION
Main input power voltages are determined by use of “jumpers” near the power transformer:
For 120v AC, jumpers are placed on JP17 and JP19 only.
For 240v AC, jumpers are placed on JP18 and “Spare Jumper” only.
Be sure that this voltage matches the intended main power voltage. The voltage selected by the jumpers MUST
MATCH the pump motor voltage and should NOT BE TOUCHED if the MPL-1000 PLUS is received as a new item.
Question and Answer IconNeed help?

Do you have a question about the Index KNIGHT MPL-1000 PLUS and is the answer not in the manual?

Index KNIGHT MPL-1000 PLUS Specifications

General IconGeneral
BrandIndex
ModelKNIGHT MPL-1000 PLUS
CategoryWater Pump
LanguageEnglish

Summary

Voltage Information

Programming Modes

Signal Mode Operation

How to operate the MPL-1000 PLUS in Signal Mode, including programming run and delay times.

Sequence Mode Operation

How to operate the MPL-1000 PLUS in Sequence Mode, including programming run and delay times.

Relay Mode Operation

How to operate the MPL-1000 PLUS in Relay Mode, where signals directly activate pumps.

Flush Manifold

Flush Valve Method of Operation

Explains how the flush manifold injects water simultaneously with chemical injection.

Enabling the Flush Valve

Steps to enable the flush valve, connect wiring, and set up the flush error buzzer.

Pump Operations

Priming the Pumps

Instructions for priming the pumps using two different methods (Method 1 and Method 2).

Calculating Pump Run Times

Guide on how to calculate the correct pump run times based on product volume and flow rate.

Optional Features

RSB-1000

Details on the RSB-1000 remote signal box for formula select and bleach defeat.

KDC-1000 Digital Counter

Information on the KDC-1000 digital counter, its function, and how to reset it.

Injector Installation

Pre-Installation Checks

Pre-installation checks including site survey, machine functions, power source, and signal voltage.

Installation Steps

Step-by-step guide for mounting the injector, running wires, connecting tubes, and powering up.

Maintenance and Technical Information

Maintenance

Guidance on lubricating and replacing pump head squeeze tubes for optimal performance.

Technical Information

Information on obtaining manuals, adapters, and contacting representatives for assistance.

Disclaimer and Warranty

Disclaimer

Knight Inc. is not responsible for misuse or non-performance outside specified instructions.

Warranty

Details on Knight's one-year warranty for controls and two-year for electronic boards.