Leak testing (to be performed in a well-
ventilated area)
Your Outdoor Patio Heater has been
checked for leaks at all the factory made
connections. To check the connection of the
gas hose/regulator/LPG cylinder.
1) Make leak test solution by mixing 1 part
washing up liquid and 3 parts water.
2) Spoon several drops (or use squirt bottle)
of the solution onto the gas hose/regulator
and regulator/LPG cylinder connection.
3) Inspect the connections and look for
bubbles.
4) If no bubbles appear, the connection is
safe.
If bubbles appear, there is leak, loosen and
re-tighten this connection. Repeat the test.
If bubbles form again, stop trying; contact
your local dealer for assistance.
Leak test annually, and whenever the gas
cylinder is removed or replaced.
Note: In the event of gas leakage, the appli-
ance must not be used or if already alight,
the gas supply must be shut off and the
appliance investigated and rectified before it
is used again.