Instructions forinstallation
Adaptation to different types of gas
To adapt the appliance to a gas different from that for which it was set up
(see label on both the packaging and the bottom of the appliance) proceed
as follows:
remove the grids
remove the covers and the spreaders
with a 7 mm socket spanner unscrew and remove the
injectors.
replace the injectors with those supplied corresponding
to the gas available (see burner and injector characte-
ristics Table)
replace the various parts proceeding in reverse.
Remember to replace the old rating plate with the new
one (supplied).
Whenever the gas pressure used is different (or variable)
from that used, install a pressure regulator which conforms to the local regu-
lations in force on the input pipe.