8
Instructions for the Installer
Overall dimensions
Width: 590mm Depth: 510mm (for model:HQ4B60A*GIK,HQ4B67A*GIK)
Width: 580mm Depth: 500mm (for model:HQ4B60B*GIK, HQ4B60B*GIK(Q),HQ4B60C*GIK,HQ4B64A*GIK,
HQ4B64A*GIK(Q))
Width: 645mm Depth: 525mm (for model:HQ4L67AAGIK)
Width: 610mm Depth: 525mm (for model:HQ4L60A*GIK,HQ4L64A*GIK,HQ4L67ABGIK,HQ3L60A*GIK,
HQ3L64A*GIK)
Width: 860mm Depth: 500mm (for model:HQ5B90AAGIK,HQ5B90BAGIK,HQ5B90CAGIK,HQ5L90AAGIK,
HQ5L90BAGIK,HQ5L90CAGIK,)
Cut out dimensions
Width: 555mm Depth: 475mm
Width: 835mm Depth: 475mm
Technical Data
Burner configuration
Wok burner(double rings burner)
Different models have different total heat input,please refer to page 1& page 2
Gas category
I Category
BE, FR, IT, LU, LV, IE, GB, GR, PT, ES, CY, CZ, LT, SK, CH, SI
LU, NL, DK, FI, SE, CY, CZ, EE, LT, LV, MT, SK, SI, BG, IS, NO, TR, HR, RO, IT, HU
FR, IT, BE, NL, DK, IE, GB, GR, ES, PT, AT, FI, SE CZ, EE, HU, LV, LT, SK, SI, IS, NO, CH, TR,
BG, HR and RO.
Note: when injectors are changed, the new one should be marked by the gas technician.
Injectors should always be changed by the authrized person.
Gas Type and working pressure:
I2H(20):G20 at 20 mbar.
I3B/P(30):G30,G31 or their mixtures at (28-30)mbar.
I3+(28-30/37):G30 at (28-30) mbar,G31 at 37mbar.