INSTALLATION PRECAUTIONS
14
Pipe Length and Additional Refrigerant
Inverter Models Capacity (Btu/h)
9K-12K 18K-24K
Lenght of pipe with standard charge
5m
5m
Maximum distance between indoor and outdoor unit
25m
25m
Additional refrigerant charge
15g/m
25g/m
Max. diff. in level between indoor and outdoor unit
10m
10m
Type of refrigerant
R32
R32
Torque Parameters
PIPE Size
Newton meter[N x m]
Pound-force foot (1bf-ft)
Kilogram-force meter (kgf-m)
1/4 ( 6.35)
18 - 20
24.4 - 27.1
2.4 - 2.7
3/8 ( 9.52)
30 - 35
40.6 - 47.4
4.1 - 4.8
1/2 ( 12)
45 - 50
61.0 - 67.7
6.2 - 6.9
5/8 ( 15.88)
60 - 65
81.3 - 88.1
8.2 - 8.9
Dedicated Distribution Device and Wire for Air Conditioner
INVERTER TYPE
MODEL capacity (Btu/h)
9k
12k
18k
24k
sectional area
Power supply cable
N
1.5mm
2
1.5mm
2
1.5mm
2
2.5mm
2
L
1.5mm
2
1.5mm
2
1.5mm
2
2.5mm
2
1.5mm
2
1.5mm
2
1.5mm
2
2.5mm
2
Connection cable
N
0.75mm
2
0.75mm
2
0.75mm
2
0.75mm
2
L or (L)
0.75mm
2
0.75mm
2
0.75mm
2
0.75mm
2
1
0.75mm
2
0.75mm
2
0.75mm
2
0.75mm
2
0.75mm
2
0.75mm
2
0.75mm
2
0.75mm
2
Note: This table is only for reference, the installation shall meet the requirements of local laws
and regulations.