EasyManua.ls Logo

Infrico Lab Care Plus CLF50086 - User Manual

Infrico Lab Care Plus CLF50086
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Ultra Low Chest Freezer
Lab Care Plus (-86ºC)
User Manual and Warranty
Question and Answer IconNeed help?

Do you have a question about the Infrico Lab Care Plus CLF50086 and is the answer not in the manual?

Overview

The Infrico Medcare Ultra Low Chest Freezer Lab Care Plus (-86°C) is a professional-grade laboratory freezer designed for ultra-low temperature storage. It is classified as CLASS I for protection against electric shock and operates under a continuous operation mode according to UNE_EN_60601. This device is manufactured under strict quality controls and is designed for use in unclassified hazardous locations or for the storage of flammable elements, provided safety measures are followed.

Function Description

The primary function of the Infrico Medcare Ultra Low Chest Freezer is to maintain ultra-low temperatures, specifically -86°C (-122.8°F), for the safe storage of samples in research and general laboratory settings. It is intended for indoor use only and requires adequate air circulation to ensure efficient refrigeration. The freezer is designed to prevent rapid temperature increases, even with frequent door openings, by replacing the air in the interior chambers. This creates an ice-free environment, which helps maintain stable temperatures and protects stored items.

Important Technical Specifications

The freezer is available in two models, CLF50086 and CLF70086, with varying capacities and dimensions.

Model CLF50086:

  • Voltage/Frequency: 230/50, 230/60, 115/60
  • Intensity (A): 5.8, 5.8, 11.31
  • Capacity (l): 500
  • Type: Horizontal
  • Door: Solid
  • Shelves: -
  • Dimensions L x W x H (Interior): 1190x640x756
  • Dimensions L x W x H (Exterior): 2011x954x1092

Model CLF70086:

  • Voltage/Frequency: 230/50, 230/60, 115/60
  • Intensity (A): 7.5, 7.5, 14.63
  • Capacity (l): 700
  • Type: Horizontal
  • Door: Solid
  • Shelves: -
  • Dimensions L x W x H (Interior): 1470x640x756
  • Dimensions L x W x H (Exterior): 2291x954x1092

General Specifications:

  • Temperature Range: -40°C to -86°C (-40°F to -122.8°F)
  • Accuracy: ± 0.1°C (± 0.2°F)
  • Display Error Values: ± 0.2°C (± 0.4°F)
  • Operating Environment: 15°C (59°F) and 30°C (86°F)
  • Storage Temperature: -15°C (5°F) to 55°C (131°F)
  • Relative Humidity (Operating): Maximum 60%
  • Relative Humidity (Storage): 20-85% (non-condensing)
  • Power Supply: 220 V, 1 phase, 50 Hz (for 8.9 A total amps)
  • Power (W): 1907 W
  • Refrigerant: R600a/R1150
  • Refrigerant Mass: 175/85 g
  • Blowing Agent: HFO
  • Freezing Power: KG/24H
  • Illumination: W
  • Lighting Volume: 700 L
  • Energy Consumption: KWH/24H
  • Climatic Class: 4(30°C.59HR)
  • Battery: 12V-12Ah rechargeable lead-acid battery for backup.

Usage Features

The freezer is equipped with a digital control panel for easy operation and monitoring.

Control Panel and Display:

  • Main Menu: Provides access to various settings and information.
  • Display Screen: Shows real-time data including time/date, battery charge status, product/cabinet temperature, set point, and status icons.
  • Operation Modes: "ON" mode (device turned on), "Stand-by" mode (device turned on but regulators off), and "OFF" mode (device not turned on).
  • Temperature Monitoring: Continuously monitors temperature with a redundant and independent system.
  • Set Point Setting: Allows users to adjust the desired temperature.
  • Battery Status: Displays the battery charge level and indicates any communication problems or anomalies.
  • Temperature Chart: Visualizes temperature trends over the last 12 hours for product and cabinet temperatures, and set point.
  • Switching Interior Light: The interior light can be turned on/off.
  • Mute Alarm: Allows users to silence audible alarms.
  • Historical Data Download: Data can be downloaded to a USB drive in .csv format.
  • Alarms: Comprehensive alarm system for various conditions such as chamber probe error, high/low temperature, power supply fault, evaporator probe error, condenser probe fault, condenser dirty, compressor usage, and defrost end time.
  • User Identification Function: Allows for user management with different access levels (User 1 to User 8 and ADMIN).
  • Language Selection: Multiple language options available (Italian, English, Spanish, French, German).

Safety Features:

  • Warnings: The manual highlights critical warnings such as the risk of fast freezing, large amounts of liquid or high water content elements, and the importance of proper installation and maintenance.
  • Obligation: Emphasizes the need to connect the device to a dedicated electrical circuit with proper grounding.
  • Prohibition: Advises against any manipulation of the device by unauthorized personnel.
  • Low Extreme Temperature: Indicates the device's capability for ultra-low temperatures.
  • Electrical Connection: Requires a dedicated outlet with correct voltage and proper grounding.
  • Unpacking: Instructions for safe unpacking, including recommendations for moving the unit forward, sideways, or backward.
  • Levelling: Ensures the apparatus is perfectly level for correct operation.
  • Rubber Gasket: Instructions for verifying and maintaining the door seal to prevent air leakage.
  • Pressure Compensation Valve: A valve that provides vacuum relief after the door openings.
  • Remote Alarm Installation: Allows for remote alarm connection.
  • Final Check-up: Steps to ensure the unit is free of packaging materials and properly connected.

Maintenance Features

Regular maintenance is crucial for the longevity and optimal performance of the freezer.

Cleaning Procedure:

  • Periodic Cleaning: Instructions for cleaning the device, including disconnecting from the mains, removing all products, and cleaning interior and exterior surfaces with soap and lukewarm water.
  • Disinfecting: Use alkaline-based or chlorine-free cleaning products.
  • Rubber Gaskets Maintenance: Regular cleaning and inspection of rubber gaskets to ensure proper sealing.
  • Condenser Cleaning: Regular cleaning of the condenser to ensure efficient operation. This involves checking the grille, cleaning with a soft brush or vacuum cleaner, and ensuring proper air circulation. The condenser filter should be cleaned every two or three months.
  • Defrosting: The unit should be defrosted once a year or whenever ice accumulation exceeds 10mm. This involves emptying all products, disconnecting the equipment, opening doors, and allowing the freezer to warm up.

Spare Parts and Technical Support:

  • Battery Replacement: The battery should be replaced every 12 months by authorized technical support.
  • Troubleshooting: A detailed section provides common problems, possible causes, and solutions to help users diagnose and resolve issues.
  • Useful Life of the Equipment: The estimated useful life is approximately 20 years, with recommendations for proper disposal of electrical and electronic equipment, batteries, and accumulators in accordance with European Union directives.

Optional Features:

  • Temperature Chart Recorder: An optional circular chart recorder can be installed to provide a physical record of temperature data.
  • CO2 Backup System: An optional CO2 backup system can be installed to maintain ultra-low temperatures in case of a power supply or cooling system failure. This system uses CO2 bottles to provide temporary cooling.

The manual also includes a warranty certificate for users to fill out with their device information.

Infrico Lab Care Plus CLF50086 Specifications

General IconGeneral
BrandInfrico
ModelLab Care Plus CLF50086
CategoryFreezer
LanguageEnglish