Cabinets
Pharma Care Series
User Manual and Warranty

Questions and Answers

  • L
    lblackAug 16, 2025
    How to troubleshoot an Infrico Pharma Care that won't turn on?
    • M
      Michael GonzalesAug 16, 2025
      If your Infrico Refrigerator isn't working, first check if the plug is properly connected to the power outlet. If it is, the fuse may have blown or the automatic current limiter may have tripped. Replace the blown fuse or reset the automatic current limiter.
  • R
    rperezAug 19, 2025
    Why is my Infrico Refrigerator not cooling properly?
    • N
      Nicholas MossAug 19, 2025
      If your Infrico Refrigerator isn't cooling sufficiently, there could be several reasons: * Check the setpoint temperature on the controller and adjust it accordingly. * Ensure the door is properly closed and minimize how often you open it. * Make sure the ventilation grilles are free from obstructions. * Clean the condenser. * Relocate the refrigerator away from direct sunlight or any other heat source.
  • J
    Janet Williams DVMAug 22, 2025
    How to fix a noisy Infrico Pharma Care Refrigerator?
    • E
      Emily KingAug 23, 2025
      If your Infrico Refrigerator is operating noisily, consider these potential causes: 1. Ensure the device is correctly leveled. 2. Rearrange any tubes inside that may be rubbing against each other. 3. Tighten any loose screws on any parts. 4. Check and fix any faulty fans in the condenser or evaporator. 5. Secure any loose parts in the condensing unit.
  • P
    Philip NicholsAug 26, 2025
    What causes high condensation pressure in an Infrico Refrigerator?
    • B
      Brenda JohnsonAug 26, 2025
      High condensation pressure in your Infrico Refrigerator can be due to several factors. You can: * Reduce the load on the unit. * Purge the system of air or non-condensable gases. * Clean the condenser. * Replace the defective condenser fan. * Relocate the device to a cooler area. * Clear any obstruction in the expansion valve or filter. * Fully open the discharge valve. * Remove any obstruction in the discharge line.
  • P
    Paul DanielsAug 28, 2025
    Why does the compressor in my Infrico Pharma Care start and stop frequently?
    • S
      steven64Aug 28, 2025
      If the compressor in your Infrico Refrigerator is cycling too frequently, it might be due to: * Differential control set at too short intervals: adjust the differential control settings. * Low refrigerant load: check the pressure and recharge the refrigerant if low. * Excessive refrigerant load: reduce the excessive refrigerant load. * Leaks in the discharge valve: repair the leaks in the discharge valve. * Opened high pressure switch: close the opened high pressure switch. * Dirty condenser: clean the condenser.
  • E
    Elizabeth HendersonAug 31, 2025
    What to do if Infrico Pharma Care Refrigerator compressor starts then shuts down?
    • F
      fmichaelAug 31, 2025
      If your Infrico Refrigerator's compressor starts but then shuts down due to overload, it could be caused by: * Low voltage: ensure the voltage is within acceptable ranges. * Faulty wiring: repair the faulty wiring. * Defective start capacitor: replace the start capacitor. * Sealed start condenser: check and repair the sealed start condenser. * Defective compressor: replace the defective compressor. * High condensation pressure: address the high condensation pressure.
  • N
    Nicole RussellSep 3, 2025
    Why is my Infrico Refrigerator running constantly?
    • R
      Rachel PriceSep 3, 2025
      If your Infrico Refrigerator is running for too long or continuously, consider the following: * Recharge with sufficient refrigerant if there is insufficient refrigerant load. * Clean or clear the condenser if it's obstructed or dirty. * Relocate the device to a cooler area if it is in a too hot area. * Repair or replace the glued controller relay. * Purge the system of air or non-condensable gases. * Check and adjust or replace the expansion valve if it is defective or incorrectly adjusted. * Ensure doors are closed promptly. * Inspect and repair insulation if it is insufficient or defective, or saturated with water. * Drain excess oil from the evaporator.
  • J
    Julie DuncanSep 6, 2025
    Why is there excessive ice buildup in my Infrico Pharma Care's evaporator?
    • N
      nancyberrySep 6, 2025
      Excessive ice in the evaporator of your Infrico Refrigerator may be due to: * Doors not being properly closed: ensure doors are properly closed. * Excessive door openings: reduce the frequency of door openings. * Defrost not being carried out: carry out the defrost process.
  • M
    Mrs. Bridget James DDSSep 9, 2025
    What causes reduced condensation pressure in Infrico Refrigerator?
    • M
      Matthew KellySep 9, 2025
      Reduced condensation pressure in your Infrico Refrigerator can be caused by: * Insufficient refrigerant load: recharge the refrigerant as necessary. * Leaks in the system: repair any leaks in the system. * Device located in a too cold area: relocate the device to a warmer area.
  • M
    Margaret WalkerSep 12, 2025
    What to do if compressor of Infrico Pharma Care does not start?
    • C
      Chad BirdSep 12, 2025
      If the compressor of your Infrico Refrigerator doesn't start, it could be due to several reasons: * Opened switch: close the opened switch. * Blown fuse: replace the blown fuse. * Faulty wiring: repair the faulty wiring. * Opened Clixon: close the opened Clixon. * Opened controller contacts (defective controller, or device located in a too cold area): fix the controller or relocate the device. * Defective relay: replace the defective relay. * Low gas load in the system - check for leaks: check for leaks and recharge gas if necessary.

Infrico Pharma Care Series Specifications

General IconGeneral
CategoryRefrigerator
Control SystemDigital
DefrostingAutomatic
LightingLED
AlarmYes
BrandInfrico
ApplicationPharmaceutical
Door TypeGlass
SeriesPharma Care