EasyManua.ls Logo

Ingersoll-Rand QX Connect Series User Manual

Ingersoll-Rand QX Connect Series
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TL-VP1T-UIM
Edition 1
October 2021
Save These Instructions
QX Connect Series
User Manual
E

Other manuals for Ingersoll-Rand QX Connect Series

Question and Answer IconNeed help?

Do you have a question about the Ingersoll-Rand QX Connect Series and is the answer not in the manual?

Ingersoll-Rand QX Connect Series Specifications

General IconGeneral
BrandIngersoll-Rand
ModelQX Connect Series
CategoryPower Tool
LanguageEnglish

Summary

Back Cap Identification

Status LEDs

Details the function of the tool's four status LEDs, including color indicators and their meanings.

Overview of Menu Screens

First Use Screen Navigation

Outlines the navigation flow for the tool's first use screen upon initial setup.

Basic Mode Screen Flow

Illustrates the screen progression and options available in the tool's Basic Mode.

Normal Mode Screen Flow

Depicts the screen progression and options available in the tool's Normal Mode.

Getting Started

Initial Screen and Interface Selection

Guides users on selecting the interface method (App, INSIGHTqcx, PCM, Standalone) upon initial setup.

INSIGHT Connect App Pairing

Instructions for pairing the tool with the INSIGHT Connect App via Bluetooth using a 6-digit code.

INSIGHTqcx Controller Pairing

Steps to set the INSIGHTqcx controller into pairing mode to establish a connection with the tool.

Switching Between Basic and Normal Modes

Standalone Basic Mode

Describes the limited menu of Basic Mode for quick setting of torque or angle targets.

Password Management

Details the default password (0000) and procedure to change it via app, controller, or ICS.

Setting the Clock

Explains how the tool's clock retains date/time during battery swaps and initial setup.

Basic Mode Configuration

Setting the Target

Instructions on how to enter Edit mode and change the target value in Basic Mode.

Torque or Angle Mode Settings

Normal Mode: PSet Configuration

PSet Selection and Editing

How to select and edit programmable PSets, including password entry for access.

Editing Target and High Limit

Guide to editing the Target and Torque High Limit parameters within a selected PSet.

PSet Parameter Editing

Torque Low Limit

Instructions for editing the Torque Low Limit parameter within a selected PSet.

Angle High Limit

Guide to editing the Angle High Limit parameter within a selected PSet.

Angle Low Limit

Instructions for editing the Angle Low Limit parameter within a selected PSet.

Torque Threshold for Counting Angle

Procedure to edit the Torque Threshold parameter for counting angle within a PSet.

Additional PSet Settings

Free Speed Adjustment

How to edit the Free Speed setting, which is a percentage of the tool's maximum speed.

Shift Down Torque and Speed

Instructions for editing Shift Down Torque and Shift Down Speed parameters.

Batch Count Configuration

Guide to editing the Batch Count, which is the number of items to be fastened per group.

Save and Drive Modes

Save/Abort Changes

Procedure to save or abort changes made to the tool's settings.

Drive Mode Selection

Explanation of Ergonomic, Performance, and Productivity modes for tool operation.

ETS Modes and Torque Units

ETS Mode Selection

How to change between direct drive and ETS modes, and select ETS mode.

Torque Units

Instructions for editing the torque units (e.g., Nm) using arrow buttons.

Fastening Direction

How to change the fastening direction between clockwise and counterclockwise.

Control Method: Torque/Angle

Procedure to change the control method between torque control and angle control.

Target and Limits Display

Target Value Explanation

Describes the target value, primary low limit, and primary high limit display.

Secondary Limits and Run Screen

Secondary Limits

Explains the secondary low and high limits for torque or angle values.

Run Screen Information

Details the Run Screen display, including last fastening result and Batch Count.

Cycle Count and Faults

Cycle Count Display

Indicates the cycle count since the last reset.

Fault/Diagnostics Display

Shows the last fault logged by the tool.

Communications and Mode Switching

Edit Communications

Procedure to edit communication settings (App, INSIGHTqcx, PCM, Standalone).

Basic/Normal Mode Switching

Steps to switch between Basic and Normal modes, including password entry.

Tool Fault Codes and Troubleshooting

Fault Codes A-10 to E-0A

Details fault codes related to Motor Controller, Communication, and Configuration issues.

Motor Controller Faults

Fault Codes E-0B to E-81

Lists fault codes for Communication timeouts, Torque/Angle limits, Plausibility, and Battery issues.

Troubleshooting PM Alarms and Firmware

PM Alarm Cycle Faults

Guides on resetting PM alarm cycle counts and time/date occurrences.

Firmware Upgrade Issues

Troubleshooting steps for invalid firmware image size, CRC, or ID.

Tool Locked Codes

Explanation of tool locked status and how to clear it via Factory Rest.