Injecta ELITE PR - Alarm and Default Parameters; Alarm Settings and Actions; Default Parameter Restoration

Injecta ELITE PR
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
0000137062 Rev. 3.0
6
Display
Relay
Actions to do
>3(3>####$OD#"+
Alarm Relay Close
- Push Enter Key to open
Alarm Relay
- Restore Product tank
/@1#1>1.'##$OD#"+
Alarm Relay open
- Push Enter Key to reset
/@1#:;/"###$OD#"+
Alarm Relay Close
- Push Enter Key to reset
G>/?#######$OD#"+
Alarm Relay open
- Restore Flow Rate
-1.1'3;3.#3../.P
Alarm Relay Open
- Press Enter Key to replace
Default parameter
- Destroy Unit
H../.#$#"+
H../.#*#"+P
H../.#*,%#'(P
Alarm Relay open
- Restore Probe or Buffer
solution and repeat calibration
function
To restore Default parameters run Following steps:
Power off Pool Basic unit
Keeping Press UP and DOWN Key switch on the
Power.
The unit will flash Q4<;)83@15>;##4/
Press up Q4<;)83@15 >;##R 3:
Enter Key to restore Default parameters.
Default parameters:
Language = UK
Set Point value= 7,4 pH; 750 mV (Rx)
Dosing Method = Acid; Low (Rx)
Time OFA = OFF
Calibration = Full
Flow Input= OFF