NIKE TL Cod. 0000136903 rev. 1.4 Page 4/4
4 DISPLAY
a) As soon as the pump is powered, the display shows 8888 for approximately 0.3 seconds, during which the pump
runs a check:
If the parameters cannot be read properly from EEPROM, the display shows FAIL and the pump remains on standby.
The default parameters can be reset using the UP key (pressed for 4 seconds).
The default parameters are:
Password = 000
T filter = 005
T delay = 005
Dosing time = 055
Lock-out time = 000
Trigger signal = HI
After the default parameters have been reset, these parameters can be modified from the programming menu (see chap.
3)
a) During the filter time, the display shows a mobile “-“ on the three red displays.
b) During the delay time, the display shows: deL
c) During the dosing time, the display shows: run
d) During lock-out, the display shows a counter which decreases to 0.
e) During priming the display shows: Pr
f) During standby the display shows: SbY
g) During manual trigger, the display shows the blinking filter, dosing and lock-out messages.
h) When idle (not included in the described cases) the display shows: on-