3.3 Device with an output 380V - 400V up to 12kW (three phase)
1. A separate electrical line is needed as device of this output.
2. The device must be connected to a separate multi polar circuit breaker of 3 x 20A.
3. The recommanded electrical cable for feeding the device is 5 x 4mm2.
4. I single - phas network, the device will be connected to a single polar circuit breaker of 60A and cable
(3 x 10mm2) or (3 x AWG -6).
For one phase or 2 x 127V(2~)
are short circuited together
1. 3 - pole switch
2. Terminal block
3. Thermostat with reset
4. Read sensor
5. Switches with lights
6. Relay
7. Heating elements
8. Thermostat
1. On/Off Switch 3 phase
2. Terminal block
3. Thermostat
4. Read sensor
5. Rocker switch
6. Transformer
7. Temp. sensor
8. Heating element
9. Triac
10. Display (Option)
11. PCBA
Model Heat Setting
kW loading
Recomended
cable size
Recomended
fuse size
220V 230V 240V
InLine - 3.0 1.0;2.0 or 3.0kW 3.0 3.3 3.6 2.5mm
2
16amps
InLine - 3.5 1.5;2.0 or 3.5kW 3.2 3.5 3.8 2.5/4mm
2
20amps
InLine - 5.0 2.0;3.0 or 5.0kW 5.0 5.5 6.0 4/6mm
2
25amps
InLine - 5.5 2.5;3.0 or 5.5kW 5.5 6.0 6.6 4/6mm
2
25-32amps
InLine - 7.0 3.0;4.0 or 7.0kW 7.0 7.7 8.3 6/10mm
2
40amps
InLine - 8.0 4.0;4.0 or 8.0kW 7.3 8.8 8.7 6/10mm
2
40amps
InLine - 9.5 4.5;5.0 or 9.5kW 8.7 9.5 10.3 10mm
2
45amps
InLine - 12 4.0;8.0 or 12.0kW 12.0 13.1 14.3 5x4mm
2
3x20amps (3 PH)
InLine - 12 4.0;8.0 or 12.0kW 12.0 13.1 14.3 3x10mm
2
60amps (1 PH)
• Operating water pressure 0.5-10 bar (7-145 psi) • Water pressure operated ow switch
• Standard 1/2"Ø compression inlet connection • Top-left and right cable entry • Bottom-left water entry
UNIT DIMENSIONS: HEIGHT 185mm WIDTH 300mm DEPTH 110mm
Directions of Assembly and Operation of “In-Line”
Instant Water Heater
An “Instant” appliance is novel device designed to supply hot water instantaneously upon
demand while conserving electricity, water and energy.
The “In-Line” is the most advanced heater in the “Instant” family and as such can be installed
anywhere, and serve any purpose. When the ow switch turns on the electrical current, the
heating element heats only the amount of water economically needed for use.
INSTANT WATER HEATER
HIDDEN INSTALLATION
(Optional)
InLine Thermostatic 12kW - 3 Phase
P.N. 115108B
Question and Answer IconNeed help?

Do you have a question about the Inline 3.0 and is the answer not in the manual?

Inline 3.0 Specifications

General IconGeneral
Power SourceElectric
Frequency50/60 Hz
Protection LevelIPX4
Voltage220-240 V
Water Pressure25-150 PSI

Summary

3.3 Device with an output 380 V - 400 V up to 12 kW (three phase)

Installation Instructions

How to Adjust Hot Water Temperature

Adjusting temperature via flow rate and electrical settings, including flow restrictors.

Thermostatic Unit Operation

Specific controls for thermostatic models, including on/off and temperature calibration.

3. INSTALLATION

3.1 Device below a sink with 220 V - 240 V up to 3.5 kW output

Installation for 3.5kW units, including electrical connection and grounding requirements.

3.2 Device below a sink with 220 V - 240 V up to 10.5 kW output

Installation for 10.5kW units, covering electrical, cable, and fuse specifications.

Device with an output 110 V; 4 kW

Installation requirements for the 110V/4kW model, including circuit breaker and cable size.