VC150 Vital Signs Monitor
Operator’s Manual
VC150 Vital Signs Monitor
English
KO00065K
© 2014 Innokas Medical
All rights reserved.
LOW RESOLUTION PDF
NOT FOR CUSTOMER PRINT!

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Innokas Medical VC150 and is the answer not in the manual?

Innokas Medical VC150 Specifications

General IconGeneral
Device TypeVital Signs Monitor
ModelVC150
ManufacturerInnokas Medical
Battery LifeUp to 8 hours
Measurement ParametersSpO2, NIBP, Temperature
DisplayLCD
Power SourceRechargeable battery
ConnectivityUSB

Summary

Introduction

About this device

Provides an overview of the VC150 vital signs monitor's capabilities and intended use for patient monitoring.

Intended use

Details the VC150 monitor's intended use for vital signs monitoring in various healthcare settings.

Safety precautions

Outlines crucial safety measures to prevent electric shock, injury, and equipment damage during operation.

Product compliance

Lists compliance classifications and standards met by the VC150 vital signs monitor.

Service requirements

Provides instructions for warranty, repair services, and contact information for Innokas Medical.

Product Overview

User interface and connections

Details the VC150 monitor's screen layout and available physical connections for peripherals.

Operating modes

Explains the different modes of operation: Clinical, Spot-check, Monitoring, and Configuration.

Monitor configuration

Describes the three types of monitor settings: current, default, and factory defaults.

Product specifications

Lists the mechanical, power, and environmental specifications of the VC150 vital signs monitor.

Getting Started

Setting up NIBP connections

Step-by-step guide for connecting NIBP hoses and cuffs for accurate blood pressure measurements.

Setting up SpO2 connections

Instructions for connecting SpO2 sensors and extension cables based on technology type.

Setting up temperature connection

Guide for connecting Welch Allyn temperature probes and covers for accurate temperature readings.

Monitor on/off

Procedure for powering the monitor on and off, including touch screen recalibration.

Alarm limit setup

Instructions on how to set up or adjust upper and lower alarm limits for individual parameters.

Monitor setup

Explains how to select options and modify settings via the Monitor Setup menu tabs.

Patient identification

Details on identifying patients and caregivers, including using barcode readers for data entry.

Alarms

Description

Explains physiological, technical, and battery alarms, including notification types.

Alarm types

Categorizes alarms into Physiological, Technical, and Battery types for clarity.

Alarm signals

Details visual and audible alarm signals, priorities, highlight colors, and LED indications.

Physiological alarm conditions

Lists physiological alarm conditions with their ranges, default limits, and priorities.

Technical alarm conditions

Provides a guide to technical alarm messages, their causes, and recommended actions.

Patient and Caregiver Data

Selecting or adding a patient

Instructions for manually entering or scanning patient IDs and adding new patient records.

Snapshots

Details on obtaining, viewing, and managing vital signs snapshots for patient data.

Deleting snapshot and notes

Procedure for deleting individual measurements within a snapshot or the entire snapshot.

Troubleshooting

Addresses common issues with the printer, EMR transmission, patient search, and barcode reader.

NIBP

Description

Explains the NIBP parameter, its technologies, and measurement principles.

NIBP modes of operation

Details the different NIBP modes: Single, STAT, Cycle, and Profile for automated measurements.

Taking NIBP measurements

Provides a comprehensive procedure for taking NIBP measurements on patients.

NIBP specifications

Lists technical specifications for NIBP, including cuff pressure range and accuracy.

NIBP troubleshooting

Guides users through common NIBP issues like overpressure and determination time.

GE TruSignal SpO2

Description

Introduces the GE TruSignal SpO2 technology for measuring arterial oxygen saturation.

SpO2 safety

Highlights factors affecting SpO2 accuracy and patient safety considerations.

SpO2 on the screen

Explains how SpO2 and Perfusion Index values are displayed on the monitor screen.

SpO2 procedure

Step-by-step instructions for connecting and applying GE TruSignal SpO2 sensors.

GE TruSignal SpO2 specifications

Provides default settings and measurement range/accuracy for GE TruSignal SpO2.

Troubleshooting

Addresses common problems with GE TruSignal SpO2 sensors and measurements.

Masimo SpO2

Description

Introduces Masimo rainbow® SET® SpO2 technology for vital signs monitoring.

SpO2 safety

Highlights safety considerations for Masimo SpO2 sensors and potential sources of error.

SpO2 on the screen

Explains the display of SpO2 values, PI, and Signal IQ on the monitor.

Masimo rainbow® SET® SpO2 and special features

Details Masimo's advanced technologies like rainbow Pulse CO-Oximetry and RAM.

Masimo sensor accuracy specification

Lists accuracy specifications for various Masimo M-LNCS, LNCS, and LNOP sensors.

Troubleshooting

Provides solutions for common Masimo SpO2 measurement and sensor connection problems.

Nellcor SpO2

Description

Introduces Nellcor OxiMax™ SpO2 technology for monitoring oxygen saturation.

SpO2 safety

Highlights safety considerations and factors affecting Nellcor SpO2 measurement accuracy.

SpO2 on the screen

Explains the display of SpO2, PI, and Perfusion Index values for Nellcor sensors.

SpO2 procedure

Step-by-step guide for connecting and applying Nellcor SpO2 sensors and monitoring respiration rate.

Nellcor SpO2 and special features

Details Nellcor's features like SatSeconds, OxiMax SPD™, and Respiration Rate theory.

Nellcor™ Sensor Technology

Explains Nellcor sensor technology, memory chip features, and calibration data.

Nellcor SpO2 specifications

Provides measurement ranges, data update, and accuracy specifications for Nellcor SpO2 sensors.

Nellcor OxiMax sensor accuracy specifications

Lists accuracy specifications for various Nellcor OxiMax sensors by model type.

Troubleshooting

Addresses common problems with Nellcor SpO2 sensors and measurement accuracy.

Pulse Rate

Description

Explains the PR measurement, its data sources, and audible heartbeat representation.

Pulse rate alarm limits

Details the adjustable upper and lower alarm limits for Pulse Rate monitoring.

Welch Allyn Temperature

Description

Details the Welch Allyn SureTemp® Plus thermometer's measurement method and display.

Safety

Outlines safety warnings and precautions for using Welch Allyn temperature measurement.

Measurement method

Explains predictive and monitoring modes for temperature measurement.

Welch Allyn temperature specifications

Lists units of measure, range, accuracy, and measurement time for Welch Allyn temperature.

Troubleshooting

Addresses issues with temperature readings and repeated error messages.

Exergen Temperature

Description

Introduces the Exergen Temporalscanner technology for temperature assessment.

Procedures for temperature determination

Guides users on how to use the Exergen temporal scanner for accurate temperature readings.

Exergen temperature specifications

Lists measurement range, accuracy, and environmental specifications for the Exergen scanner.

Troubleshooting

Addresses problems with measurement accuracy and scanner readings.

Battery

Description

Details the rechargeable Li-Ion battery, its indicators, and operating status.

Battery charging

Provides instructions and warnings for charging the monitor's Li-Ion battery pack.

Battery charge level

Explains how to interpret battery indicators and charge levels on the monitor screen.

Storage, care, and replacement of batteries

Guidance on storing, caring for, and replacing the monitor's batteries.

Troubleshooting

Addresses issues like the monitor not turning on or the battery not lasting long.

Default Setup

General

Configures general monitor settings like alarm volume, system time, and measurement expiration.

Alarm defaults

Sets default parameter-specific alarm limits and priority, which persist after restart.

Visual settings

Allows customization of parameter colors and waveform display on the home screen.

NIBP profile setup

Enables the creation and configuration of custom NIBP measurement profiles.

Connections

Connections

Details the monitor's available connections for NIBP, SpO2, USB, Welch Allyn, and remote alarm.

Maintenance

Service and parts

Information on obtaining service, spare parts, and contacting customer support.

User maintenance schedule

Outlines recommended daily and monthly maintenance procedures for monitor uptime.

Calibration

Explains that only touch screen recalibration is user-accessible.

Cleaning

Provides lists of approved and prohibited cleaning agents for the monitor and accessories.

Battery and monitor storage care

Guidance on storing the monitor and accessories, including battery care for short and extended periods.

Repairs

Details the process for obtaining warranty or non-warranty repair services.

Disposal of product waste

Guidelines for the proper disposal or recycling of batteries, patient-applied parts, and the monitor.

Principles of Noninvasive Blood Pressure Determination (NIBP)

DINAMAP SuperSTAT algorithm

Explains the oscillometric method and algorithm used for NIBP measurements.

DINAMAP Auscultatory Reference Algorithm

Describes the auscultatory method for NIBP determination using Korotkoff sounds.

Supplemental Analysis of Clinical Accuracy Test Data

GE TruSignal V2

Presents Bland-Altman plots and analysis for GE TruSignal V2 SpO2 measurement accuracy.

Clinical test results

Summarizes clinical test results for GE SpO2 sensors against reference values.

Nellcor accuracy study results

Presents SpO2 accuracy data for Nellcor sensors compared to CO-oximeters.

Masimo sensor accuracy

Provides performance specifications and accuracy data for Masimo sensors.

Performance Specifications for Masimo M-LNCS, LNCS, and LNOP Adhesive Sensors

Details accuracy values for Masimo M-LNCS, LNCS, and LNOP adhesive sensors.

Performance specifications for Rainbow ReSposable Pulse CO-Oximeter Sensor System

Lists accuracy values for Rainbow ReSposable sensors with Masimo SET Oximetry.

Performance Specifications for Masimo Sensors SpO2 Multisite Reusable Sensors

Provides accuracy data for Masimo M-LNCS/LNCS/LNOP Multisite sensors.

Performance Specifications for DBI™ Series

Lists accuracy values for DBI sensors with Masimo SET Oximetry Technology.