Overview

This document is an installation manual for the Innova OKKI air-conditioning unit, designed for large spaces such as industrial warehouses and extensive areas. It provides comprehensive information for installers and users, ensuring correct management, safe operation, and optimal performance with minimal energy consumption.

The OKKI unit is an advanced air-conditioning system that features a SmartJet system on its indoor unit. This innovative system includes motorized and self-directing nozzles that autonomously and independently regulate the direction and temperature of the air. This prevents air stratification and ensures the maintenance of the desired temperature in the occupied area, providing maximum comfort and cost-effectiveness.

Technical Specifications:

The unit is available in two sizes with different flow rates: OKKI 15 kW and OKKI 30 kW.

Heating Performance (A 7/6; A 20):

  • OKKI 15 kW:
    • Nominal total output power: 13.40 kW
    • Minimum total output power: 3.40 kW
    • Maximum total output power: 16.00 kW
    • COP: 3.76 (maximum-minimum: 5.23-3.03)
  • OKKI 30 kW:
    • Nominal total output power: 28.00 kW
    • Minimum total output power: 5.50 kW
    • Maximum total output power: 29.00 kW
    • COP: 3.71 (maximum-minimum: 5.00-3.05)

Cooling Performance (A 35; A 27/19):

  • OKKI 15 kW:
    • Nominal total output power: 13.40 kW
    • Minimum total output power: 3.30 kW
    • Maximum total output power: 15.00 kW
    • EER: 3.26 (maximum-minimum: 5.08-2.93)
  • OKKI 30 kW:
    • Nominal total output power: 23.20 kW
    • Minimum total output power: 6.10 kW
    • Maximum total output power: 27.00 kW
    • EER: 3.24 (maximum-minimum: 4.59-2.56)

Airflow Performance:

  • OKKI 15 kW:
    • Nominal air flow rate: 2500 m³/h
    • Available pressure: 170 Pa
  • OKKI 30 kW:
    • Nominal air flow rate: 5000 m³/h
    • Available pressure: 170 Pa

Room Side Fan:

  • Type: Radial
  • Number: 1 (OKKI 15 kW), 2 (OKKI 30 kW)
  • Maximum absorbed power: 400 W (both models)

Sound Levels:

  • OKKI 15 kW:
    • Sound power radiated in the Lw channel: 60.0 dB(A)
    • Average sound pressure at 5 m Lp: 39.0 dB(A)
  • OKKI 30 kW:
    • Sound power radiated in the Lw channel: 64.0 dB(A)
    • Average sound pressure at 5 m Lp: 42.0 dB(A)

Electrical Characteristics:

  • Power supply: 400/3/50 V/ph/Hz
  • OKKI 15 kW:
    • Nominal absorbed power: 4.11 kW
    • Total absorbed current: 6.24 A
  • OKKI 30 kW:
    • Nominal absorbed power: 7.16 kW
    • Total absorbed current: 10.88 A
  • Protection rating: IP X2

Product Dimensions:

  • OKKI 15 kW:
    • Width: 1010 mm
    • Depth: 893 mm
    • Height: 802 mm
    • Weight: 75.0 kg
  • OKKI 30 kW:
    • Width: 1360 mm
    • Depth: 953 mm
    • Height: 1026 mm
    • Weight: 97.0 kg

Connections:

  • Air connections: 355 mm (both models)
  • Condensate drain connection: 30 mm (both models)

Usage Features:

The OKKI unit is designed for indoor installation in a vertical position, fixed to a wall. It is crucial to select an installation site that is well-ventilated and away from heat sources, obstacles, or environments with flammable gases or high humidity. The minimum floor area required for installation varies based on the refrigerant charge, with specific values provided in the manual to prevent accumulation of leaked refrigerant.

The unit supports various configurations: Smart jet, Manual jet, and Ducted. It can be controlled via a remote control, which is a touch screen keyboard. This electronic control panel allows for:

  • Adjustment of room temperature.
  • Management of the main functions of the device.
  • Temperature measurement.
  • Adjustment of fan speed.
  • Display of return air temperature.
  • Internal memory with data storage even in the event of abnormal shutdown or power failure.
  • Multi-unit configuration, allowing linkage of multiple units under a single command via Modbus or Wi-Fi.

The unit can be connected to a thermostat for integration mode, a clean contact for summer/winter selection, and a device for remote power on/off. It also provides a generic alarm signaling connection. For multi-unit installations, one controller can manage up to 8 devices.

Maintenance Features:

Routine maintenance is essential for the optimal functioning and longevity of the OKKI unit. An annual maintenance plan, to be carried out by qualified personnel or a Technical Service Centre, includes:

Electrical Circuit Checks:

  • Verification of electrical supply voltage and absorption.
  • Tightening of connections.
  • Inspection for damage or wear to electrical cables.
  • Checking gaskets and sealing materials to ensure they prevent flammable atmospheres.
  • Correct fixing of cable glands.
  • Safety device checks.

Mechanical Checks:

  • Tightening of screws, fans, and electrical box components, as well as the unit's external paneling.
  • Assessment of the structural integrity.
  • Treatment of oxidized parts with suitable paints to prevent or reduce oxidation.

Hydraulic Controls:

  • Verification of regular condensate drainage.
  • Cleaning of condensate collection trays.
  • Cleaning of exhaust ducts.

Airflow Controls:

  • Verification of regular airflow.
  • Cleaning of intake grids.
  • Cleaning of ducting.

Cleaning:

  • Cleaning of the aesthetic cover.
  • Cleaning or replacement of filters.
  • Cleaning of the heat exchanger.

Filters should be removed by disconnecting the power supply and gently sliding them upwards. If the filters are acceptable, they can be cleaned with a vacuum cleaner or low-pressure compressor; otherwise, they must be replaced. The heat exchanger should be cleaned carefully with a vacuum cleaner or low-pressure compressor, ensuring not to touch the fins and cleaning in the opposite direction to the air flow to prevent dirt from entering.

The manual also includes a troubleshooting table for various alarms and their remedies, such as issues with probes, communication errors, and compressor malfunctions. It emphasizes that certain functional aspects, like compressor restart delays or periodic defrosting cycles, are normal and not indicative of faults.

Innova OKKI Specifications

General IconGeneral
BrandInnova
ModelOKKI
CategorySafety Equipment
LanguageEnglish