LIMITED WARRANTY
Always use the cover when the transmitter is
not in the configuration phase. The cover
prevents the transmitter from getting dirt on
the soldering pads as well as getting ESD by
accidental touch of the soldering pads.
Connect input, output and power supply acc.
to fig. 2.
A convinient way to install the transmitter is
to use the INOR mounting kits for in-head and
DIN rail mounting, see figure 4 and 5. In order
to minimize measuring errors make sure the
connecting screws are tightened enough.
INOR Process AB, or any other affiliated company within the Inor Group (hereinafter jointly referred
to as ”Inor”), hereby warrants that the Product will be free from defects in materials or workmanship
for a period of five (5) years from the date of delivery (”Limited Warranty”). This Limited Warranty
is limited to repair or replacement at Inor’s option and is effective only for the first end-user of the
Product. Upon receipt of a warranty claim, Inor shall respond within a reasonable time period as to
its decision concerning:
1 Whether Inor acknowledges its responsibility for any asserted defect in
materials or workmanship; and, if so,
2 the appropriate cause of action to be taken (i.e. whether a defective product should be
replaced or repaired by Inor).
This Limited Warranty applies only if the Product:
1 is installed according to the instructions furnished by Inor;
2 is connected to a proper power supply;
3 is not misused or abused; and
4 there is no evidence of tampering, mishandling, neglect, accidental damage,
modification or repair without the approval of Inor or damage done to the Product by
anyone other than Inor.
This Limited Warranty is provided by Inor and contains the only express warranty provided.
INOR SPECIFICALLY DISCLAIMS ANY EXPRESS WARRANTY NOT PROVIDED HEREIN
AND ANY IMPLIED WARRANTY, GUARANTEE OR REPRESENTATION AS TO SUITABILITY
FOR ANY PARTICULAR PURPOSE, PERFORMANCE, QUALITY AND ABSENCE OF ANY
HIDDEN DEFECTS, AND ANY REMEDY FOR BREACH OF CONTRACT, WHICH BUT FOR
THIS PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION OF LAW, CUSTOM OF
TRADE OR COURSE OF DEALING, INCLUDING IMPLIED WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. EXCEPT AS PROVIDED
HEREIN, INOR FURTHER DISCLAIMS ANY RESPONSIBILITY FOR LOSSES, EXPENSES,
INCONVENIENCES, SPECIAL, DIRECT, SECONDARY OR CONSEQUENTIAL DAMAGES
ARISING FROM OWNERSHIP OR USE OF THE PRODUCT.
Products that are covered by the Limited Warranty will either be repaired or replaced at the option of
Inor. Customer pays freight to Inor, and Inor will pay the return freight by post or other “normal”
way of transport. If any other type of return freight is requested, customer pays the whole return
cost.
Power supply: 6.5 to 32 VDC
Input: Pt100 (α=0.00385) 3-wire
Configuration Zero-point: -50 to +50°C
-60 to +120°F
Configuration Span: 50, 100, 150, 200, 300,
400, 500°C
100, 200, 300,
400, 600, 800, 1000°F
Adjustment Span: ±10% of span
(±5% for 600, 800, 1000°F)
Output: 4-20 mA temperature linear
Operating temperature: -40 to +85°C
-40 to +185°F
IN-HEAD MOUNTING DIN RAIL MOUNTING
Head mounting
kit (APAQ-HRF)
70ADA00011
Rail mounting kit 70ADA00013
INSTALLATION
DATA (shortform)
Adjustable In-head
Temperature Transmitters
for Pt100 Sensors
USER
INSTRUCTIONS
SWEDEN
GERMANY
USA
ADDRESS 1860 Renaissance Blvd., Suite 203
Sturtevant, WI 53177, USA
PHONE Domestic 1-888-430-INOR
(262) 884-4535
International +1-262-884-4535
FAX Domestic (262) 884-4537
International +1-262-884-4537
E-MAIL sales@inor.com
ADDRESS PO Box 9125
S-200 39 MALMÖ, Sweden
PHONE Domestic 040-31 25 60
International +46-40-31 25 60
FAX Domestic 040-31 25 70
International +46-40-31 25 70
E-MAIL support@inor.se
ADDRESS Rodenbacher Chaussee 6
Gebäude 805
D-63457 Hanau-Wolfgang
PHONE Domestic 06181-582940
International +49-6181-582940
FAX Domestic 06181-582944
International +49-6181-582944
E-MAIL inor.gmbh@t-online.de
www.inor.com
The manual must be read prior to adjustment
and/or installation. All information subject to
change without notice.
MADE IN SWEDEN
MEASURING MADE A LITTLE EASIER
86BAQ00004 2001-04
DIMENSIONS
Question and Answer IconNeed help?

Do you have a question about the INOR APAQ-HRF and is the answer not in the manual?

Summary

Installation and Dimensions

Installation Overview

General guidelines for transmitter installation, including ESD precautions and using mounting kits.

Physical Dimensions

Provides the physical dimensions of the APAQ-HRF transmitter in mm and inches.

Mounting Types

Details on In-Head Mounting kit (70ADA00011) and DIN Rail Mounting kit (70ADA00013).

Technical Data and Specifications

Shortform Data

Key technical specifications including power supply, input type, configuration range, output, and operating temperature.

Load Diagram

Graph illustrating the relationship between supply voltage and load resistance for the transmitter output.

Configuration Procedure

Zero-Point Configuration

Setting the zero-point for temperature measurement using solder jumpers as shown in Figure 3.

Span Configuration

Selecting the desired temperature span (in °C or °F) via solder jumpers according to Tables 1 and 2.

Burn-Out Detection

Configuring the burn-out detection feature (upscale/downscale) using solder jumpers as per Table 3.

Calibration Procedure

Initial Setup and Stabilization

Connect the transmitter, apply input, and allow 15 minutes for stabilization before adjustment.

Zero-Point Adjustment

Apply minimum input signal and adjust the Z-potentiometer to achieve 4.00 mA output.

Span Adjustment

Apply maximum input signal and adjust the S-potentiometer to achieve 20.00 mA output, repeating as needed.

Finalizing Calibration

Secure the potentiometers with lacquer to complete the calibration process.