PART 2 INSTALLATION INSTRUCTIONS
8
®
CA-3 & DA-3 Technical Manual 2018 www.insingermachine.com 800-344-4802
MECHANICAL CONNECTIONS
Flush all lines to remove debris.
Connect 140°F water lines for tank lls/booster as
tagged and noted on the installation drawings.
If machine is provided with steam heat, connect the
steam lines and steam condensate lines as tagged
and noted on installation drawings.
Connect the drain lines.
CAUTION:
Drain lines must be as specied on installation
drawings. Drain line should be properly vented and
should have fall of not less than 1/4” to the foot of
proper ow.
CAUTION:
Some area plumbing codes require drains to ow
into an open gap with an opening twice the diameter
of the pipe. Check with your local plumbing codes for
the type of drain connection required.
CAUTION:
Do not reduce the size of lines as specied in
installation drawings. All lines are sized to facilitate
necessary ows, pressures, etc.
CAUTION:
When connecting on the 24VAC control voltage
side of the transformer, total KVA must not exceed
50VA.
The detergent density probe should be placed in the
hole provided.
HVAC
Ventilation system should be sized to provide adequate
ventilation per machine specs. Refer to spec sheet.
CHEMICALS
Upon completed installation of the dishmachine,
contact a local detergent/chemical supplier for the
correct chemicals for your machine.
Electrical connection points for the detergent dispenser
and rinse injector are located inside the control panel.
Refer to the machine wiring diagram for the proper
connection points.
Dispensers may be connected on either the primary
voltage side of the machine or the 24VAC control
voltage side.